PV Firefighter Switch: PV Generator Disconnection for Photovoltaic Systems

Technical explanation of safe PV generator disconnection – from DC string disconnection to optional AC-side shutdown logic.

QFire Firefighter Switch Fuses in positive and negative poles Surge protection T1+2 integrated Sheet steel enclosure for industrial environments All cable entries from below — clean & protected cable handling Made in Germany — developed & built by Q3 ENERGIE

PV firefighter switch – briefly explained

A firefighter switch for photovoltaic systems disconnects PV strings on the DC side and galvanically isolates them from the inverter in the event of activation. The aim is to de-energise the DC cables from the installation point of the switching unit towards the inverter.

PV modules can continue to generate voltage when exposed to light. Generator-side disconnection therefore reduces dangerous DC voltages inside the building or along long cable routes. Modern systems such as QFire are designed according to IEC 60947-3 and can be triggered automatically, manually or via external control signals, depending on the system design.

QFire Firefighter Switch for 8 Strings with Surge Protection T1+2

Photovoltaic systems can generate DC voltages of up to 1,500 V. Even when the inverter is switched off, the DC string cables may remain live.

In emergency situations, this can:

A firefighter safety switch enables galvanic disconnection of the PV strings directly at the building entry point or close to the roof entry.

QFire PV firefighter safety switch installed in practice for safe PV generator disconnection and emergency DC shutdown
Firefighter switches QFire for 4,7 MWp

How Does a PV Firefighter Safety Switch Work?

A firefighter safety switch disconnects the PV strings automatically or manually from the inverter by galvanic isolation in emergency situations. Typical system components include:

[1] Switch Boxes installed close to the roof entry point
[2] Control Box located in the inverter area
[3] Optional external emergency stop and interface to the fire alarm system

Optional components include:
■ integration of a fire alarm system
■ integrated surge protection
■ integrated fuses in the positive and/or negative pole
■ cluster technology for multiple roof areas
■ integration into an AC-side shutdown concept

In the event of shutdown, all PV strings are galvanically isolated so that the cables between the firefighter safety switch and the inverter become de-energised.

Structure of the QFire PV Firefighter Safety Switch System
Firefighter switches QFire 24 strings with surge protection

Q3 PV firefighter switch QFire LITE | BIG at a glance

RequirementQFire LITEQFire BIG
System typesmaller to medium-sized PV systemslarger commercial PV systems
System designcompact standard solutioncentral Control Box with Switch Boxes
Expandabilitystandardised, not cascadablemodular and cascadable
Triggering
e.g. grid failure, external signal, emergency stop
grid failure, emergency stop, Control Box, FAS/FACP
Typical applicationsimple rooftop systems, smaller commercial systemslarge rooftops, multiple roof areas, public buildings, industrial sites
Planningstandardisedproject-specific
LinkView QFire LITE for smaller PV systems →View QFire BIG for large PV systems →
PV firefighter safety switch with generator-side DC shutdown close to the PV generator
Cluster Steuerbox für mehrere Generatorflächen

Safe triggering in the event of fire or fault:
Shutdown mechanisms for PV firefighter switches in emergency and fault scenarios

Multiple triggering methods ensure reliable shutdown in emergency situations — manually, automatically or via external control signals.

The QFire firefighter safety switch can be triggered in several different ways. In addition to manual shutdown via the control unit or external emergency stop buttons, the system also responds automatically to defined fault conditions.

In the event of grid failure or undervoltage, the relays automatically open and galvanically disconnect the connected PV strings from the inverter. This ensures that the safety function remains active even if the supply voltage fails.
The system also detects cable breakage or voltage drops within the control circuit and automatically initiates a safe shutdown.

Technische Details
QFire LITE firefighter safety switch for photovoltaic systems – standardised and cost-efficient solution
Customised QFire BIG firefighter safety switch solution for photovoltaic systems
External emergency stop button for the QFire PV firefighter safety switch
External key switch for the QFire PV firefighter safety switch
Break-glass emergency stop for the QFire PV firefighter safety switch
Cluster Steuerbox für mehrere Generatorflächen

QFire cluster system: coordinated DC shutdown of multiple generator fields

Example: five generator fields, each with its own Cluster Control Box, with common triggering via one central external emergency stop

QFire cluster system with five generator fields, one QFire Cluster Control Box per generator field, star-shaped connection of five clusters per field and one central external emergency stop for common triggering via the interconnected Cluster Control Boxes.<br/>A central external emergency stop / key switch triggers the connected Cluster Control Boxes together. DC disconnection is carried out within the respective generator fields.

Each generator field has its own QFire Cluster Control Box. Each Cluster Control Box connects five clusters within the field in a star-shaped configuration.

All five Cluster Control Boxes are interconnected and can be triggered together via one central external emergency stop.

A central external emergency stop / key switch can trigger all connected Cluster Control Boxes together. DC disconnection is then carried out within the respective generator fields.

Technische Details

What is important when planning a PV firefighter switch?

When planning a firefighter switch for PV systems, the number of strings is not the only decisive factor. Cable routes, roof entry points, inverter structure, MPPT allocation, surge protection, possible fire alarm systems, external emergency stop points and the question of whether several roof areas or generator fields need to be shut down together are also important.

For smaller systems, a standardised solution such as QFire LITE may be sufficient. For larger commercial systems, public buildings, multiple roof areas or complex shutdown concepts, project-specific planning with QFire BIG is usually the better choice.

Q3 AI SQAY helps with planning PV firefighter switches
QFire Feuerwehrschalter Technik Referenz
Easy installation: no internal wiring of the control cables to terminal blocks required
Referenzanlage Feuerwehrschalter Firma Ladenburger - Bild während Bau - vielen Dank an e.systeme21
Technischer Hintergrund

PV firefighter safety switches can be integrated into a wide range of photovoltaic system concepts, including:

Commercial photovoltaic systems

Industrial and ground-mounted solar installations

Rooftop photovoltaic systems with multiple inverters

Technischer Hintergrund

Who Is the QFire BIG System Designed For?

Customised QFire BIG firefighter safety switch solution for photovoltaic systems

The QFire system was specifically developed to meet the requirements of planners, installers and EPC companies.
Thanks to its modular architecture, clearly defined system logic and simplified installation concept, the system can be integrated into a wide variety of photovoltaic system designs in compliance with applicable standards.

The combination of technical safety, scalability and easy handling makes QFire a future-proof solution for photovoltaic systems of all sizes.

Who Is the QFire LITE System Designed For?

QFire LITE firefighter safety switch for photovoltaic systems – standardised and cost-efficient solution

The QFire LITE system is the standardised solution for small and medium-sized photovoltaic systems. It is based on the same proven safety principle as QFire BIG, but designed as a compact, non-expandable solution.

QFire LITE is particularly suitable for straightforward photovoltaic system concepts where simple integration, a limited number of strings, clear system structures and cost-efficient implementation are key priorities.

Cluster Steuerbox für mehrere Generatorflächen
Presse
Technische Details
Photovoltaik Feuerwehrschalter Schulung

Online Training for the QFire PV Firefighter Safety Switch

Firefighter Switch PV – Online Training for Planners and Installers
Inverter with integrated DC isolator

When is a firefighter switch mandatory?

Whether a firefighter switch is required for a PV system depends on the specific installation. Key factors include cable routes, building type, fire protection concept, regional requirements and tender specifications. For long DC cable routes inside the building or for larger commercial PV systems, generator-side disconnection is often technically advisable and frequently required in practice.

FAQ – Feuerwehrschalter und Brandschutz bei PV-Anlagen
Firefighter Switch FAQ
QFire Feuerwehrschalter für 8 Strings mit Überspannungsschutz T1+2
GAK mit Überspannungsschutz DC Anschlusstechnik kundenspezifisch für x MPP Tracker optional mit Sicherungen, DC Freischalter
AC Box AC Anschlusstechnik mit Überspannungsschutz und NH Trenner 250 A TN-C