{"id":7483,"date":"2026-01-29T15:26:15","date_gmt":"2026-01-29T14:26:15","guid":{"rendered":"https:\/\/q3-energie.de\/technical-solutions-for-photovoltaic-systems\/dc-connection-technology-for-photovoltaic-systems-up-to-1500-v-dc\/"},"modified":"2026-05-27T15:13:43","modified_gmt":"2026-05-27T13:13:43","slug":"pv-string-combiner","status":"publish","type":"page","link":"https:\/\/q3-energie.de\/en\/technic\/pv-string-combiner\/","title":{"rendered":"DC connection technology for photovoltaic systems up to 1,500 V DC"},"content":{"rendered":"\n<div class=\"wp-block-cover alignfull\" style=\"min-height:603px;aspect-ratio:unset;\"><img loading=\"lazy\" decoding=\"async\" width=\"1920\" height=\"500\" class=\"wp-block-cover__image-background wp-image-2475 size-full\" alt=\"DC-Anschlusstechnik PV - Generatoranschlussk\u00e4sten - DC Combiner\" src=\"https:\/\/neu.q3-energie.de\/wp-content\/uploads\/2026\/02\/DC-Anschlusstechnik-PV-Generatoranschlusskaesten-DC-Combiner-e1778932019122.webp\" data-object-fit=\"cover\" title=\"\" srcset=\"https:\/\/q3-energie.de\/wp-content\/uploads\/2026\/02\/DC-Anschlusstechnik-PV-Generatoranschlusskaesten-DC-Combiner-e1778932019122.webp 1920w, https:\/\/q3-energie.de\/wp-content\/uploads\/2026\/02\/DC-Anschlusstechnik-PV-Generatoranschlusskaesten-DC-Combiner-e1778932019122-300x78.webp 300w, https:\/\/q3-energie.de\/wp-content\/uploads\/2026\/02\/DC-Anschlusstechnik-PV-Generatoranschlusskaesten-DC-Combiner-e1778932019122-1024x267.webp 1024w, https:\/\/q3-energie.de\/wp-content\/uploads\/2026\/02\/DC-Anschlusstechnik-PV-Generatoranschlusskaesten-DC-Combiner-e1778932019122-768x200.webp 768w, https:\/\/q3-energie.de\/wp-content\/uploads\/2026\/02\/DC-Anschlusstechnik-PV-Generatoranschlusskaesten-DC-Combiner-e1778932019122-1536x400.webp 1536w\" sizes=\"auto, (max-width: 1920px) 100vw, 1920px\" \/><span aria-hidden=\"true\" class=\"wp-block-cover__background has-background-dim-60 has-background-dim\"><\/span><div class=\"wp-block-cover__inner-container is-layout-flow wp-block-cover-is-layout-flow\">\n<div class=\"wp-block-columns alignfull are-vertically-aligned-center is-layout-flex wp-container-core-columns-is-layout-5b0bc1de wp-block-columns-is-layout-flex\" style=\"padding-top:var(--wp--preset--spacing--50);padding-right:var(--wp--preset--spacing--50);padding-bottom:var(--wp--preset--spacing--50);padding-left:var(--wp--preset--spacing--50)\">\n<div class=\"wp-block-column is-vertically-aligned-center is-layout-flow wp-block-column-is-layout-flow\" style=\"padding-top:0;padding-right:var(--wp--preset--spacing--50);padding-bottom:0;padding-left:var(--wp--preset--spacing--50);flex-basis:65%\">\n<h1 class=\"wp-block-heading has-text-align-left has-nv-text-dark-bg-color has-text-color has-large-font-size\">PV String Combiner Boxes for Commercial and Utility-Scale Solar Systems<\/h1>\n\n\n\n<div style=\"height:30px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<h2 class=\"wp-block-heading has-text-align-left has-nv-text-dark-bg-color has-text-color\" style=\"font-size:18px\"><strong>Custom string combiner solutions up to 1,500 V DC for photovoltaic systems with central or string inverter architecture.<\/strong><\/h2>\n\n\n\n<div style=\"height:9px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<div class=\"wp-block-buttons has-custom-font-size hero-cta has-x-large-font-size is-horizontal is-layout-flex wp-block-buttons-is-layout-flex\" style=\"padding-top:0;padding-bottom:0\">\n<div class=\"wp-block-button has-custom-width wp-block-button__width-50 is-style-primary\"><a class=\"wp-block-button__link has-border-color has-nv-site-bg-border-color has-medium-font-size has-custom-font-size wp-element-button\" href=\"#schutz\" style=\"border-width:2px;border-top-left-radius:4px;border-top-right-radius:4px;border-bottom-left-radius:4px;border-bottom-right-radius:4px;padding-top:var(--wp--preset--spacing--30);padding-right:var(--wp--preset--spacing--20);padding-bottom:var(--wp--preset--spacing--30);padding-left:var(--wp--preset--spacing--20)\">Protective functions and safety in the DC range \u2192<\/a><\/div>\n\n\n\n<div class=\"wp-block-button has-custom-width wp-block-button__width-50 is-style-secondary\"><a class=\"wp-block-button__link has-border-color has-nv-site-bg-border-color has-medium-font-size has-custom-font-size wp-element-button\" href=\"#fehler\" style=\"border-width:2px;border-top-left-radius:4px;border-top-right-radius:4px;border-bottom-left-radius:4px;border-bottom-right-radius:4px;padding-top:var(--wp--preset--spacing--30);padding-right:var(--wp--preset--spacing--20);padding-bottom:var(--wp--preset--spacing--30);padding-left:var(--wp--preset--spacing--20)\">Typical planning errors in DC connection technology \u2192<\/a><\/div>\n\n\n\n<div class=\"wp-block-button has-custom-width wp-block-button__width-50 is-style-secondary\"><a class=\"wp-block-button__link has-border-color has-nv-site-bg-border-color has-medium-font-size has-custom-font-size wp-element-button\" href=\"#sicherheit\" style=\"border-width:2px;border-top-left-radius:4px;border-top-right-radius:4px;border-bottom-left-radius:4px;border-bottom-right-radius:4px;padding-top:var(--wp--preset--spacing--30);padding-right:var(--wp--preset--spacing--20);padding-bottom:var(--wp--preset--spacing--30);padding-left:var(--wp--preset--spacing--20)\">Why is DC connection technology safety-critical? \u2192<\/a><\/div>\n\n\n\n<div class=\"wp-block-button has-custom-width wp-block-button__width-50 is-style-primary\"><a class=\"wp-block-button__link has-border-color has-nv-site-bg-border-color has-medium-font-size has-custom-font-size wp-element-button\" href=\"#\u00fcberblick\" style=\"border-width:2px;border-top-left-radius:4px;border-top-right-radius:4px;border-bottom-left-radius:4px;border-bottom-right-radius:4px;padding-top:var(--wp--preset--spacing--30);padding-right:var(--wp--preset--spacing--20);padding-bottom:var(--wp--preset--spacing--30);padding-left:var(--wp--preset--spacing--20)\">Our DC connection technology at a glance \u2192<\/a><\/div>\n<\/div>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-vertically-aligned-center is-layout-flow wp-block-column-is-layout-flow\"><div class=\"wp-block-image\">\n<figure class=\"aligncenter size-full is-resized\"><img loading=\"lazy\" decoding=\"async\" width=\"800\" height=\"800\" src=\"https:\/\/q3-energie.de\/wp-content\/uploads\/2026\/02\/Generatoranschlusskaesten-GAK-DC-Combiner-DC-Anschlusstechnik-PV.webp\" alt=\"PV String Combiner Boes - Generator Connection Boxes GAK - DC Combiner - DC Connection Technology PV\" class=\"wp-image-2476\" style=\"width:400px\" title=\"\" srcset=\"https:\/\/q3-energie.de\/wp-content\/uploads\/2026\/02\/Generatoranschlusskaesten-GAK-DC-Combiner-DC-Anschlusstechnik-PV.webp 800w, https:\/\/q3-energie.de\/wp-content\/uploads\/2026\/02\/Generatoranschlusskaesten-GAK-DC-Combiner-DC-Anschlusstechnik-PV-300x300.webp 300w, https:\/\/q3-energie.de\/wp-content\/uploads\/2026\/02\/Generatoranschlusskaesten-GAK-DC-Combiner-DC-Anschlusstechnik-PV-150x150.webp 150w, https:\/\/q3-energie.de\/wp-content\/uploads\/2026\/02\/Generatoranschlusskaesten-GAK-DC-Combiner-DC-Anschlusstechnik-PV-768x768.webp 768w\" sizes=\"auto, (max-width: 800px) 100vw, 800px\" \/><\/figure>\n<\/div><\/div>\n<\/div>\n<\/div><\/div>\n\n\n\n<div class=\"wp-block-cover alignfull has-neve-text-color-color has-text-color has-link-color wp-elements-bad4c778c4d44470f633a88d7f51d177\" style=\"padding-top:var(--wp--preset--spacing--50);padding-right:var(--wp--preset--spacing--50);padding-bottom:var(--wp--preset--spacing--50);padding-left:var(--wp--preset--spacing--50)\"><img loading=\"lazy\" decoding=\"async\" width=\"1920\" height=\"800\" class=\"wp-block-cover__image-background wp-image-465 size-full\" alt=\"Technischer Hintergrund\" src=\"https:\/\/q3-energie.de\/wp-content\/uploads\/2026\/01\/Background2_1920px.webp\" data-object-fit=\"cover\" title=\"\" srcset=\"https:\/\/q3-energie.de\/wp-content\/uploads\/2026\/01\/Background2_1920px.webp 1920w, https:\/\/q3-energie.de\/wp-content\/uploads\/2026\/01\/Background2_1920px-300x125.webp 300w, https:\/\/q3-energie.de\/wp-content\/uploads\/2026\/01\/Background2_1920px-1024x427.webp 1024w, https:\/\/q3-energie.de\/wp-content\/uploads\/2026\/01\/Background2_1920px-768x320.webp 768w, https:\/\/q3-energie.de\/wp-content\/uploads\/2026\/01\/Background2_1920px-1536x640.webp 1536w\" sizes=\"auto, (max-width: 1920px) 100vw, 1920px\" \/><span aria-hidden=\"true\" class=\"wp-block-cover__background has-nv-text-dark-bg-background-color has-background-dim-80 has-background-dim\"><\/span><div class=\"wp-block-cover__inner-container is-layout-flow wp-block-cover-is-layout-flow\">\n<div class=\"wp-block-columns alignwide has-neve-link-color-color has-text-color has-link-color wp-elements-6458341bc1b0955c976f17fba7fe67ac is-layout-flex wp-container-core-columns-is-layout-0fb72d45 wp-block-columns-is-layout-flex\" style=\"padding-top:0;padding-right:0;padding-bottom:0;padding-left:0\">\n<div class=\"wp-block-column is-vertically-aligned-bottom has-nv-site-bg-color has-text-color has-link-color wp-elements-d072895a17460e87c47938795e1ae70b is-layout-flow wp-block-column-is-layout-flow\" style=\"padding-top:0;padding-right:0;padding-bottom:0;padding-left:0;flex-basis:100%\">\n<div style=\"height:50px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<h2 class=\"wp-block-heading has-neve-text-color-color has-text-color has-link-color wp-elements-65f1e58c5df5123ddab4b700e70c6326\" style=\"font-size:28px\">PV String Combiner: DC Connection Technology<\/h2>\n\n\n\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-8f761849 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\" style=\"padding-top:var(--wp--preset--spacing--50);padding-right:0;padding-bottom:var(--wp--preset--spacing--50);padding-left:0;flex-basis:66.66%\">\n<p class=\"has-neve-text-color-color has-text-color has-link-color wp-elements-b0a21e637d5cf741ab772711e93513cf wp-block-paragraph\" style=\"font-size:16px\">DC connection technology forms the safety-critical interface between the PV module array and the inverter.<br>Here, multiple strings are connected in parallel, protected, monitored, and routed to the respective MPP tracker in compliance with standards.<br><br>At system voltages of up to 1,500 V DC, DC connection technology performs a central protective function.<br>It prevents reverse currents, protects inverters from overvoltage, and ensures a standard-compliant disconnection and isolation option according to IEC 60947-3.<\/p>\n\n\n\n<h3 class=\"wp-block-heading has-neve-text-color-color has-text-color has-link-color wp-elements-6c05afeb1d480f2e9d370b422779450b\" style=\"font-size:16px\"><br>For larger systems, the PV string combiner boxes additionally handles:<br><br><strong>\u25a0 Switching and isolation functions<br>\u25a0 Integration of firefighter switches<\/strong><br><strong>\u25a0 <\/strong>String monitoring and status messages<strong><br>\u25a0 Project-specific interconnection concepts<\/strong><\/h3>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-vertically-aligned-center is-layout-flow wp-block-column-is-layout-flow\" style=\"padding-top:var(--wp--preset--spacing--50);padding-right:var(--wp--preset--spacing--50);padding-bottom:var(--wp--preset--spacing--50);padding-left:var(--wp--preset--spacing--50);flex-basis:33.33%\">\n<h3 class=\"wp-block-heading has-neve-text-color-color has-text-color has-link-color wp-elements-7d86a38009a20e8abba0b8901ed4876c\" style=\"font-size:16px\">Depending on the system size, this bundling takes place in:<br><\/h3>\n\n\n\n<div class=\"wp-block-group dc-card animated fadeInRight is-nowrap is-layout-flex wp-container-core-group-is-layout-6e81cd72 wp-block-group-is-layout-flex\" style=\"padding-top:0;padding-bottom:0\">\n<div id=\"wp-block-themeisle-blocks-font-awesome-icons-21e3f7a1\" class=\"wp-block-themeisle-blocks-font-awesome-icons\"><span class=\"wp-block-themeisle-blocks-font-awesome-icons-container nan-padding\"><svg viewbox=\"0 0 1800 1800\"><path d=\"M872.831,1326.446c-1.999,0.113-3.853-0.183-5.733-0.53c-6.064-1.076-11.863-3.945-16.53-8.611 l-514.859-514.86c-5.852-5.855-9.138-13.792-9.138-22.068c0-8.275,3.287-16.212,9.142-22.067L455.5,638.535 c12.189-12.185,31.954-12.185,44.126,0l373.109,373.1l727.884-727.89c12.189-12.185,31.949-12.185,44.131,0l119.788,119.784 c5.855,5.851,9.142,13.792,9.142,22.067s-3.286,16.212-9.137,22.063l-869.649,869.645 C889.043,1323.155,881.106,1326.446,872.831,1326.446z M401.905,780.377l470.825,470.83l825.614-825.61l-75.657-75.653 l-727.885,727.889c-12.19,12.186-31.95,12.186-44.13,0L477.563,704.729L401.905,780.377z\"><\/path><path d=\"M1692.376,662.67c22.568,75.209,34.758,154.872,34.758,237.334c0,456.08-371.054,827.129-827.138,827.129 c-456.08,0-827.129-371.05-827.129-827.129c0-456.084,371.049-827.138,827.129-827.138c213.186,0,407.787,81.086,554.605,214.022 l44.161-44.165C1340.604,98.513,1130.391,10.456,899.996,10.456c-490.494,0-889.54,399.051-889.54,889.548 s399.046,889.54,889.54,889.54c490.498,0,889.548-399.042,889.548-889.54c0-100.372-16.734-196.909-47.517-286.985 L1692.376,662.67z\"><\/path><\/svg><\/span><\/div>\n\n\n\n<h3 class=\"wp-block-heading has-text-align-left has-neve-text-color-color has-text-color has-link-color wp-elements-9b8a61e5609530b280a42da3b2b2fed4\" style=\"font-size:20px\"><strong>String boxes<\/strong><\/h3>\n<\/div>\n\n\n\n<div style=\"height:15px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<div class=\"wp-block-group dc-card animated fadeInRight delay-1s is-nowrap is-layout-flex wp-container-core-group-is-layout-8f761849 wp-block-group-is-layout-flex\">\n<div id=\"wp-block-themeisle-blocks-font-awesome-icons-190c6b65\" class=\"wp-block-themeisle-blocks-font-awesome-icons\"><span class=\"wp-block-themeisle-blocks-font-awesome-icons-container nan-padding\"><svg viewbox=\"0 0 1800 1800\"><path d=\"M872.831,1326.446c-1.999,0.113-3.853-0.183-5.733-0.53c-6.064-1.076-11.863-3.945-16.53-8.611 l-514.859-514.86c-5.852-5.855-9.138-13.792-9.138-22.068c0-8.275,3.287-16.212,9.142-22.067L455.5,638.535 c12.189-12.185,31.954-12.185,44.126,0l373.109,373.1l727.884-727.89c12.189-12.185,31.949-12.185,44.131,0l119.788,119.784 c5.855,5.851,9.142,13.792,9.142,22.067s-3.286,16.212-9.137,22.063l-869.649,869.645 C889.043,1323.155,881.106,1326.446,872.831,1326.446z M401.905,780.377l470.825,470.83l825.614-825.61l-75.657-75.653 l-727.885,727.889c-12.19,12.186-31.95,12.186-44.13,0L477.563,704.729L401.905,780.377z\"><\/path><path d=\"M1692.376,662.67c22.568,75.209,34.758,154.872,34.758,237.334c0,456.08-371.054,827.129-827.138,827.129 c-456.08,0-827.129-371.05-827.129-827.129c0-456.084,371.049-827.138,827.129-827.138c213.186,0,407.787,81.086,554.605,214.022 l44.161-44.165C1340.604,98.513,1130.391,10.456,899.996,10.456c-490.494,0-889.54,399.051-889.54,889.548 s399.046,889.54,889.54,889.54c490.498,0,889.548-399.042,889.548-889.54c0-100.372-16.734-196.909-47.517-286.985 L1692.376,662.67z\"><\/path><\/svg><\/span><\/div>\n\n\n\n<h3 class=\"wp-block-heading has-text-align-left has-neve-text-color-color has-text-color has-link-color has-medium-font-size wp-elements-db9aa1df53f92cced933dee26e0e0680\"><strong>String Combiner Boxes (SCB)<\/strong><\/h3>\n<\/div>\n\n\n\n<div style=\"height:15px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<div class=\"wp-block-group dc-card fadeInRight animated delay-2s is-nowrap is-layout-flex wp-container-core-group-is-layout-8f761849 wp-block-group-is-layout-flex\">\n<div id=\"wp-block-themeisle-blocks-font-awesome-icons-c889f492\" class=\"wp-block-themeisle-blocks-font-awesome-icons\"><span class=\"wp-block-themeisle-blocks-font-awesome-icons-container nan-padding\"><svg viewbox=\"0 0 1800 1800\"><path d=\"M872.831,1326.446c-1.999,0.113-3.853-0.183-5.733-0.53c-6.064-1.076-11.863-3.945-16.53-8.611 l-514.859-514.86c-5.852-5.855-9.138-13.792-9.138-22.068c0-8.275,3.287-16.212,9.142-22.067L455.5,638.535 c12.189-12.185,31.954-12.185,44.126,0l373.109,373.1l727.884-727.89c12.189-12.185,31.949-12.185,44.131,0l119.788,119.784 c5.855,5.851,9.142,13.792,9.142,22.067s-3.286,16.212-9.137,22.063l-869.649,869.645 C889.043,1323.155,881.106,1326.446,872.831,1326.446z M401.905,780.377l470.825,470.83l825.614-825.61l-75.657-75.653 l-727.885,727.889c-12.19,12.186-31.95,12.186-44.13,0L477.563,704.729L401.905,780.377z\"><\/path><path d=\"M1692.376,662.67c22.568,75.209,34.758,154.872,34.758,237.334c0,456.08-371.054,827.129-827.138,827.129 c-456.08,0-827.129-371.05-827.129-827.129c0-456.084,371.049-827.138,827.129-827.138c213.186,0,407.787,81.086,554.605,214.022 l44.161-44.165C1340.604,98.513,1130.391,10.456,899.996,10.456c-490.494,0-889.54,399.051-889.54,889.548 s399.046,889.54,889.54,889.54c490.498,0,889.548-399.042,889.548-889.54c0-100.372-16.734-196.909-47.517-286.985 L1692.376,662.67z\"><\/path><\/svg><\/span><\/div>\n\n\n\n<h3 class=\"wp-block-heading has-text-align-left has-neve-text-color-color has-text-color has-link-color has-medium-font-size wp-elements-084e620d26929cf8ef20e15909089886\"><strong>DC combiner boxes for large-scale systems<\/strong><\/h3>\n<\/div>\n\n\n\n<div style=\"height:15px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<\/div><\/div>\n\n\n\n<div class=\"wp-block-cover alignfull has-medium-font-size\" style=\"padding-top:var(--wp--preset--spacing--50);padding-right:var(--wp--preset--spacing--50);padding-bottom:var(--wp--preset--spacing--50);padding-left:var(--wp--preset--spacing--50)\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"427\" class=\"wp-block-cover__image-background wp-image-465 size-large\" alt=\"Technischer Hintergrund\" src=\"https:\/\/q3-energie.de\/wp-content\/uploads\/2026\/01\/Background2_1920px-1024x427.webp\" data-object-fit=\"cover\" title=\"\" srcset=\"https:\/\/q3-energie.de\/wp-content\/uploads\/2026\/01\/Background2_1920px-1024x427.webp 1024w, https:\/\/q3-energie.de\/wp-content\/uploads\/2026\/01\/Background2_1920px-300x125.webp 300w, https:\/\/q3-energie.de\/wp-content\/uploads\/2026\/01\/Background2_1920px-768x320.webp 768w, https:\/\/q3-energie.de\/wp-content\/uploads\/2026\/01\/Background2_1920px-1536x640.webp 1536w, https:\/\/q3-energie.de\/wp-content\/uploads\/2026\/01\/Background2_1920px.webp 1920w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><span aria-hidden=\"true\" class=\"wp-block-cover__background has-nv-text-dark-bg-background-color has-background-dim-80 has-background-dim\"><\/span><div class=\"wp-block-cover__inner-container is-layout-constrained wp-container-core-cover-is-layout-a48333fe wp-block-cover-is-layout-constrained\">\n<div style=\"height:100px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<div class=\"wp-block-columns alignwide is-layout-flex wp-container-core-columns-is-layout-8f761849 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<h2 class=\"wp-block-heading alignwide has-neve-text-color-color has-text-color has-link-color wp-elements-1dcdf41859cf01384731ec35533abefb\" id=\"schutz\">PV String Combiner: Protective functions + Safety<\/h2>\n\n\n\n<p class=\"has-neve-text-color-color has-text-color has-link-color wp-elements-a9db23c874ea1f804bcb74c14aba2fc8 wp-block-paragraph\" style=\"font-size:16px\">In PV systems with system voltages up to 1,500 V DC, DC connection technology plays a central role in safety, availability, and compliance with standards.<br><br>Q3 integrates protective and monitoring functions tailored to the system concept, module type, and grid requirements \u2013 from standard solutions to project-specific large-scale systems.<\/p>\n<\/div>\n<\/div>\n\n\n\n<div class=\"wp-block-columns alignwide has-neve-text-color-color has-text-color has-link-color wp-elements-393f2eb1bb020e55bd97cd2e4ed55231 is-layout-flex wp-container-core-columns-is-layout-4c3d31c9 wp-block-columns-is-layout-flex\" style=\"padding-top:0;padding-right:0;padding-bottom:0;padding-left:0\">\n<div class=\"wp-block-column is-vertically-aligned-top dc-card has-nv-light-bg-background-color has-background is-layout-flow wp-block-column-is-layout-flow\" style=\"border-top-left-radius:8px;border-top-right-radius:8px;border-bottom-left-radius:8px;border-bottom-right-radius:8px;border-left-color:var(--wp--preset--color--neve-text-color);border-left-width:1px;padding-top:var(--wp--preset--spacing--50);padding-right:var(--wp--preset--spacing--50);padding-bottom:var(--wp--preset--spacing--50);padding-left:var(--wp--preset--spacing--50);flex-basis:50%\">\n<div class=\"wp-block-group is-nowrap is-layout-flex wp-container-core-group-is-layout-8f761849 wp-block-group-is-layout-flex\"><div class=\"wp-block-image\">\n<figure class=\"aligncenter size-thumbnail is-resized\"><img loading=\"lazy\" decoding=\"async\" width=\"150\" height=\"150\" src=\"https:\/\/neu.q3-energie.de\/wp-content\/uploads\/2026\/02\/Ueberspannungsschutz-150x150.webp\" alt=\"DC surge protection\" class=\"wp-image-1637\" style=\"width:100px\" title=\"\"><\/figure>\n<\/div>\n\n\n<h3 class=\"wp-block-heading has-neve-text-color-color has-text-color has-link-color has-medium-font-size wp-elements-5c78f541fcf270fcde246b3d8a280ecf\">Surge protection T1+T2 (optionally integrated)<\/h3>\n<\/div>\n\n\n\n<div style=\"height:30px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<p class=\"wp-block-paragraph\" style=\"font-size:16px\">Integrated DC surge protection modules (Type 1+2) <br>limit transient overvoltages resulting from<br><br><br><strong>\u25a0 direct or nearby lightning strikes<br>\u25a0 switching operations in the grid<br>\u25a0 inductive coupling<\/strong><\/p>\n\n\n\n<p class=\"wp-block-paragraph\" style=\"font-size:16px\">The design is project-specific \u2013 taking into account:<br><\/p>\n\n\n\n<p class=\"wp-block-paragraph\" style=\"font-size:16px\"><strong>\u25a0 System voltage up to 1,500 V DC<br>\u25a0 Grounding and lightning protection concept<br>\u25a0 Cable lengths and installation environment<\/strong><\/p>\n\n\n\n<p class=\"wp-block-paragraph\" style=\"font-size:16px\">Optionally, the SPD modules used feature a potential-free remote signaling contact that transmits the status (e.g., triggering or module defect) to higher-level monitoring or control systems.<\/p>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-vertically-aligned-top dc-card has-nv-light-bg-background-color has-background is-layout-flow wp-block-column-is-layout-flow\" style=\"border-top-left-radius:8px;border-top-right-radius:8px;border-bottom-left-radius:8px;border-bottom-right-radius:8px;border-left-color:var(--wp--preset--color--neve-text-color);border-left-width:1px;padding-top:var(--wp--preset--spacing--50);padding-right:var(--wp--preset--spacing--50);padding-bottom:var(--wp--preset--spacing--50);padding-left:var(--wp--preset--spacing--50)\">\n<div class=\"wp-block-group is-nowrap is-layout-flex wp-container-core-group-is-layout-8f761849 wp-block-group-is-layout-flex\"><div class=\"wp-block-image\">\n<figure class=\"aligncenter size-thumbnail is-resized\"><img loading=\"lazy\" decoding=\"async\" width=\"150\" height=\"150\" src=\"https:\/\/q3-energie.de\/wp-content\/uploads\/2026\/02\/Sicherung-oder-Diode-150x150.webp\" alt=\"\" class=\"wp-image-2527\" style=\"width:100px\" title=\"\" srcset=\"https:\/\/q3-energie.de\/wp-content\/uploads\/2026\/02\/Sicherung-oder-Diode-150x150.webp 150w, https:\/\/q3-energie.de\/wp-content\/uploads\/2026\/02\/Sicherung-oder-Diode-300x300.webp 300w, https:\/\/q3-energie.de\/wp-content\/uploads\/2026\/02\/Sicherung-oder-Diode.webp 400w\" sizes=\"auto, (max-width: 150px) 100vw, 150px\" \/><\/figure>\n<\/div>\n\n\n<h3 class=\"wp-block-heading has-neve-text-color-color has-text-color has-link-color has-medium-font-size wp-elements-b2f300295a1538102fbe695a764604af\">String fuse or diode?<\/h3>\n<\/div>\n\n\n\n<div style=\"height:30px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<p class=\"wp-block-paragraph\" style=\"font-size:16px\">With strings connected in parallel, reverse currents can occur if a string is faulty or shaded. Depending on the module type, short-circuit current (Isc), and system concept, different protection strategies are used: <\/p>\n\n\n\n<h4 class=\"wp-block-heading\" style=\"font-size:16px\"><strong>String fuses<\/strong><\/h4>\n\n\n\n<p class=\"wp-block-paragraph\" style=\"font-size:16px\"><strong>\u25a0 reliable protection against fault currents<\/strong><br><strong>\u25a0 replaceable in case of triggering<br><strong>\u25a0 <\/strong>proven standard solution in the commercial sector<\/strong><\/p>\n\n\n\n<h4 class=\"wp-block-heading\" style=\"font-size:16px\"><strong>Blocking diodes<\/strong><br><br><strong>\u25a0 permanently block reverse currents<\/strong><br><strong><strong>\u25a0 <\/strong>no replacement components required<\/strong><br><strong>\u25a0 useful for special system concepts<\/strong><\/h4>\n\n\n\n<p class=\"wp-block-paragraph\" style=\"font-size:16px\">Q3 assists in selecting the appropriate protection strategy, taking into account module technology, number of strings, and service concept.<\/p>\n<\/div>\n<\/div>\n\n\n\n<div class=\"wp-block-columns alignwide has-neve-text-color-color has-text-color has-link-color wp-elements-10d21f3e066ba1eb3fdd017f0d634a81 is-layout-flex wp-container-core-columns-is-layout-4c3d31c9 wp-block-columns-is-layout-flex\" style=\"padding-top:0;padding-right:0;padding-bottom:0;padding-left:0\">\n<div class=\"wp-block-column is-vertically-aligned-top dc-card has-nv-light-bg-background-color has-background is-layout-flow wp-block-column-is-layout-flow\" style=\"border-top-left-radius:8px;border-top-right-radius:8px;border-bottom-left-radius:8px;border-bottom-right-radius:8px;border-left-color:var(--wp--preset--color--neve-text-color);border-left-width:1px;padding-top:var(--wp--preset--spacing--50);padding-right:var(--wp--preset--spacing--50);padding-bottom:var(--wp--preset--spacing--50);padding-left:var(--wp--preset--spacing--50);flex-basis:50%\">\n<h3 class=\"wp-block-heading has-neve-text-color-color has-text-color has-link-color has-medium-font-size wp-elements-89b50271ca08c7639745d74dc22c67d7\">Reverse current protection<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\" style=\"font-size:16px\">Reverse current protection prevents currents from parallel strings <br>from flowing back into a damaged string. <br><br><br>This<br><br><strong>\u25a0 reduces hot-spot risks<br>\u25a0 protects modules from thermal overload<br>\u25a0 stabilizes system operation<\/strong><br><br><br>Especially with a high number of strings per MPP, a clean design is crucial.<\/p>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-vertically-aligned-top dc-card has-nv-light-bg-background-color has-background is-layout-flow wp-block-column-is-layout-flow\" style=\"border-top-left-radius:8px;border-top-right-radius:8px;border-bottom-left-radius:8px;border-bottom-right-radius:8px;border-left-color:var(--wp--preset--color--neve-text-color);border-left-width:1px;padding-top:var(--wp--preset--spacing--50);padding-right:var(--wp--preset--spacing--50);padding-bottom:var(--wp--preset--spacing--50);padding-left:var(--wp--preset--spacing--50)\">\n<h3 class=\"wp-block-heading has-neve-text-color-color has-text-color has-link-color has-medium-font-size wp-elements-edcdd0e8bd5e754149c043cc7f919d36\">DC switch-disconnectors<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\" style=\"font-size:16px\">DC switch-disconnectors enable safe, standard-compliant isolation between the module array and the inverter. They are used for: <br><br><strong>\u25a0 Maintenance and service<br>\u25a0 defined shutdown scenarios<br>\u25a0 integration into safety concepts (e.g., firefighter switches)<\/strong><br><br>Design and dimensioning are carried out to match:<br><br><strong>\u25a0 System voltage<br>\u25a0 Operating and short-circuit current<br>\u25a0 Switching concept of the system<\/strong><br><\/p>\n<\/div>\n<\/div>\n\n\n\n<div class=\"wp-block-columns alignwide has-neve-text-color-color has-text-color has-link-color wp-elements-41833c1216fab45f7e82150b84a91f43 is-layout-flex wp-container-core-columns-is-layout-4c3d31c9 wp-block-columns-is-layout-flex\" style=\"padding-top:0;padding-right:0;padding-bottom:0;padding-left:0\">\n<div class=\"wp-block-column is-vertically-aligned-top dc-card has-nv-light-bg-background-color has-background is-layout-flow wp-block-column-is-layout-flow\" style=\"border-top-left-radius:8px;border-top-right-radius:8px;border-bottom-left-radius:8px;border-bottom-right-radius:8px;border-left-color:var(--wp--preset--color--neve-text-color);border-left-width:1px;padding-top:var(--wp--preset--spacing--50);padding-right:var(--wp--preset--spacing--50);padding-bottom:var(--wp--preset--spacing--50);padding-left:var(--wp--preset--spacing--50);flex-basis:50%\">\n<div class=\"wp-block-group is-nowrap is-layout-flex wp-container-core-group-is-layout-8f761849 wp-block-group-is-layout-flex\"><div class=\"wp-block-image is-style-default\">\n<figure class=\"aligncenter size-thumbnail is-resized\"><img loading=\"lazy\" decoding=\"async\" width=\"150\" height=\"150\" src=\"https:\/\/q3-energie.de\/wp-content\/uploads\/2026\/02\/Dashboard-150x150.webp\" alt=\"\" class=\"wp-image-2529\" style=\"width:100px\" title=\"\" srcset=\"https:\/\/q3-energie.de\/wp-content\/uploads\/2026\/02\/Dashboard-150x150.webp 150w, https:\/\/q3-energie.de\/wp-content\/uploads\/2026\/02\/Dashboard-300x300.webp 300w, https:\/\/q3-energie.de\/wp-content\/uploads\/2026\/02\/Dashboard.webp 400w\" sizes=\"auto, (max-width: 150px) 100vw, 150px\" \/><\/figure>\n<\/div>\n\n\n<h3 class=\"wp-block-heading has-neve-text-color-color has-text-color has-link-color has-medium-font-size wp-elements-0e302ffa2addb5e9086eaab0265b1cb9\">Monitoring and status messages<\/h3>\n<\/div>\n\n\n\n<div style=\"height:30px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<p class=\"wp-block-paragraph\" style=\"font-size:16px\">Depending on the version, the following states can be recorded in string combiner boxes and DC combiner systems:<\/p>\n\n\n\n<p class=\"wp-block-paragraph\" style=\"font-size:16px\"><strong>\u25a0 Current values per string<br>\u25a0 Switch positions of DC switch-disconnectors<br>\u25a0 Status of the surge protection (remote signaling contact)<\/strong><\/p>\n\n\n\n<p class=\"wp-block-paragraph\" style=\"font-size:16px\">Collective fault signals<br><br>Monitoring can be integrated directly into the connection box and supports operators in rapid fault localization and predictable maintenance.<\/p>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-vertically-aligned-top dc-card has-nv-light-bg-background-color has-background is-layout-flow wp-block-column-is-layout-flow\" style=\"border-top-left-radius:8px;border-top-right-radius:8px;border-bottom-left-radius:8px;border-bottom-right-radius:8px;border-left-color:var(--wp--preset--color--neve-text-color);border-left-width:1px;padding-top:var(--wp--preset--spacing--50);padding-right:var(--wp--preset--spacing--50);padding-bottom:var(--wp--preset--spacing--50);padding-left:var(--wp--preset--spacing--50)\">\n<div class=\"wp-block-group is-nowrap is-layout-flex wp-container-core-group-is-layout-8f761849 wp-block-group-is-layout-flex\"><div class=\"wp-block-image\">\n<figure class=\"aligncenter size-thumbnail is-resized\"><img loading=\"lazy\" decoding=\"async\" width=\"150\" height=\"150\" src=\"https:\/\/q3-energie.de\/wp-content\/uploads\/2026\/02\/Einzelstringueberwachung-150x150.webp\" alt=\"\" class=\"wp-image-2530\" style=\"width:100px\" title=\"\" srcset=\"https:\/\/q3-energie.de\/wp-content\/uploads\/2026\/02\/Einzelstringueberwachung-150x150.webp 150w, https:\/\/q3-energie.de\/wp-content\/uploads\/2026\/02\/Einzelstringueberwachung-300x300.webp 300w, https:\/\/q3-energie.de\/wp-content\/uploads\/2026\/02\/Einzelstringueberwachung.webp 400w\" sizes=\"auto, (max-width: 150px) 100vw, 150px\" \/><\/figure>\n<\/div>\n\n\n<h3 class=\"wp-block-heading has-neve-text-color-color has-text-color has-link-color has-medium-font-size wp-elements-947d45c61f7ef77173d4754693f786e7\">Individual string current monitoring<\/h3>\n<\/div>\n\n\n\n<div style=\"height:30px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<p class=\"wp-block-paragraph\" style=\"font-size:16px\">For large-scale systems and demanding O&amp;M concepts, individual string current monitoring enables precise recording of current and voltage at the string level. <br><br>Deviations are detected early \u2013 before they lead to noticeable yield losses. <br><br>Particularly relevant for:<br><br><strong>\u25a0 PV power plants in the MW range<br>\u25a0 high string density per inverter<br>\u25a0 performance guarantees<\/strong><\/p>\n<\/div>\n<\/div>\n<\/div><\/div>\n\n\n\n<div style=\"height:100px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<h2 class=\"wp-block-heading alignwide has-neve-text-color-color has-text-color has-link-color wp-elements-38981381e60a55170a8873c33476b4dc\" id=\"fehler\" style=\"font-size:20px\">Typical planning errors in PV string combiners<\/h2>\n\n\n\n<div class=\"wp-block-columns alignwide is-layout-flex wp-container-core-columns-is-layout-8f761849 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<p class=\"has-neve-text-color-color has-text-color has-link-color wp-elements-ce2d9a0b293efec535e9f5bd59798ea0 wp-block-paragraph\" style=\"font-size:16px\">When designing string combiner boxes and DC combiner systems, detailed planning determines operational safety, ease of service, and yield. In practice, similar error patterns occur repeatedly \u2013 these can be reliably avoided through early coordination and dimensioning in accordance with standards. <\/p>\n<\/div>\n<\/div>\n\n\n\n<div class=\"wp-block-columns has-neve-text-color-color has-text-color has-link-color wp-elements-1fa51c6af0fbd1fbf213c3d64f97dd63 is-layout-flex wp-container-core-columns-is-layout-f54850f0 wp-block-columns-is-layout-flex\" style=\"padding-top:var(--wp--preset--spacing--50);padding-right:0;padding-bottom:var(--wp--preset--spacing--50);padding-left:0\">\n<div class=\"wp-block-column is-vertically-aligned-top has-nv-text-dark-bg-background-color has-background is-layout-flow wp-block-column-is-layout-flow\" style=\"border-top-left-radius:8px;border-top-right-radius:8px;border-bottom-left-radius:8px;border-bottom-right-radius:8px;padding-top:var(--wp--preset--spacing--40);padding-right:var(--wp--preset--spacing--40);padding-bottom:var(--wp--preset--spacing--40);padding-left:var(--wp--preset--spacing--40);flex-basis:50%\">\n<h3 class=\"wp-block-heading dc-card has-neve-text-color-color has-text-color has-background has-link-color wp-elements-84ed3c421511408b000c046a1e1301db\" style=\"border-top-left-radius:8px;border-top-right-radius:8px;border-bottom-left-radius:8px;border-bottom-right-radius:8px;border-right-style:none;border-right-width:0px;border-left-color:var(--wp--preset--color--neve-text-color);border-left-width:1px;background-color:#f5f6f79e;padding-top:var(--wp--preset--spacing--50);padding-right:var(--wp--preset--spacing--50);padding-bottom:var(--wp--preset--spacing--50);padding-left:var(--wp--preset--spacing--50);font-size:16px\">Parallel connection without a clean reverse current concept<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\" style=\"font-size:16px\"><em>Strings are connected in parallel without properly designing reverse current conditions and protection strategies (fuses\/diodes).<\/em><\/p>\n\n\n\n<p class=\"wp-block-paragraph\" style=\"font-size:16px\"><strong>Typical consequences: <\/strong>unwanted reverse currents, thermal stress, yield losses in the event of a fault.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Better: <\/strong>Derive the protection strategy from Isc, number of strings per MPP, module type, and temperature conditions.<\/p>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-vertically-aligned-top has-nv-text-dark-bg-background-color has-background is-layout-flow wp-block-column-is-layout-flow\" style=\"border-top-left-radius:8px;border-top-right-radius:8px;border-bottom-left-radius:8px;border-bottom-right-radius:8px;padding-top:var(--wp--preset--spacing--40);padding-right:var(--wp--preset--spacing--40);padding-bottom:var(--wp--preset--spacing--40);padding-left:var(--wp--preset--spacing--40)\">\n<h3 class=\"wp-block-heading dc-card has-neve-text-color-color has-text-color has-background has-link-color wp-elements-522eb3052c794dbc7eccf100b108c225\" style=\"border-top-left-radius:8px;border-top-right-radius:8px;border-bottom-left-radius:8px;border-bottom-right-radius:8px;border-right-style:none;border-right-width:0px;border-left-color:var(--wp--preset--color--neve-text-color);border-left-width:1px;background-color:#f5f6f79e;padding-top:var(--wp--preset--spacing--50);padding-right:var(--wp--preset--spacing--50);padding-bottom:var(--wp--preset--spacing--50);padding-left:var(--wp--preset--spacing--50);font-size:16px\">String fuses incorrectly dimensioned or incorrectly selected<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\" style=\"font-size:16px\"><strong>Typical consequences: <\/strong>unnecessary triggering or insufficient protection.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Better: <\/strong>Dimensioning based on short-circuit current, parallel connection factor, temperature, and component approvals.<\/p>\n<\/div>\n<\/div>\n\n\n\n<div class=\"wp-block-columns has-neve-text-color-color has-text-color has-link-color wp-elements-56e8121c726f18a554a32c03db97c5d9 is-layout-flex wp-container-core-columns-is-layout-f54850f0 wp-block-columns-is-layout-flex\" style=\"padding-top:var(--wp--preset--spacing--50);padding-right:0;padding-bottom:var(--wp--preset--spacing--50);padding-left:0\">\n<div class=\"wp-block-column is-vertically-aligned-top has-nv-text-dark-bg-background-color has-background is-layout-flow wp-block-column-is-layout-flow\" style=\"border-top-left-radius:8px;border-top-right-radius:8px;border-bottom-left-radius:8px;border-bottom-right-radius:8px;padding-top:var(--wp--preset--spacing--40);padding-right:var(--wp--preset--spacing--40);padding-bottom:var(--wp--preset--spacing--40);padding-left:var(--wp--preset--spacing--40);flex-basis:50%\">\n<h3 class=\"wp-block-heading dc-card has-neve-text-color-color has-text-color has-background has-link-color wp-elements-f929d559b882d9b24757b5d8c90767ef\" style=\"border-top-left-radius:8px;border-top-right-radius:8px;border-bottom-left-radius:8px;border-bottom-right-radius:8px;border-right-style:none;border-right-width:0px;border-left-color:var(--wp--preset--color--neve-text-color);border-left-width:1px;background-color:#f5f6f79e;padding-top:var(--wp--preset--spacing--50);padding-right:var(--wp--preset--spacing--50);padding-bottom:var(--wp--preset--spacing--50);padding-left:var(--wp--preset--spacing--50);font-size:16px\">Surge protection (SPD) not matching the lightning protection\/grounding concept<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\" style=\"font-size:16px\"><em><em>SPD design and installation location are chosen without properly including the lightning protection concept, cable routing, and grounding\/equipotential bonding structure.<\/em><\/em><\/p>\n\n\n\n<p class=\"wp-block-paragraph\" style=\"font-size:16px\"><strong>Typical consequences: <\/strong>protection that is too weak or unnecessary over-dimensioning, additional maintenance cases.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Better: <\/strong>Align the SPD concept with the lightning protection class, cable lengths, and system voltage; integrate status messages (remote signaling contact) into the monitoring system.<\/p>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-vertically-aligned-top has-nv-text-dark-bg-background-color has-background is-layout-flow wp-block-column-is-layout-flow\" style=\"border-top-left-radius:8px;border-top-right-radius:8px;border-bottom-left-radius:8px;border-bottom-right-radius:8px;padding-top:var(--wp--preset--spacing--40);padding-right:var(--wp--preset--spacing--40);padding-bottom:var(--wp--preset--spacing--40);padding-left:var(--wp--preset--spacing--40)\">\n<h3 class=\"wp-block-heading dc-card has-neve-text-color-color has-text-color has-background has-link-color wp-elements-36bd0df14e9bf30ac294a6ac59f0424f\" style=\"border-top-left-radius:8px;border-top-right-radius:8px;border-bottom-left-radius:8px;border-bottom-right-radius:8px;border-right-style:none;border-right-width:0px;border-left-color:var(--wp--preset--color--neve-text-color);border-left-width:1px;background-color:#f5f6f79e;padding-top:var(--wp--preset--spacing--50);padding-right:var(--wp--preset--spacing--50);padding-bottom:var(--wp--preset--spacing--50);padding-left:var(--wp--preset--spacing--50);font-size:16px\">DC switching and isolation technology not consistently designed for 1,500 V DC<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\"><em>DC switch-disconnectors\/load-break switches are used that do not match the voltage, current, arc conditions, and application in detail.<\/em><\/p>\n\n\n\n<p class=\"wp-block-paragraph\" style=\"font-size:16px\"><strong>Typical consequences: <\/strong>impermissible heating, reduced service life, risk during service.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Better: <\/strong>Select switching devices explicitly according to system voltage, operating\/short-circuit current, and shutdown scenario.<\/p>\n<\/div>\n<\/div>\n\n\n\n<div class=\"wp-block-columns has-neve-text-color-color has-text-color has-link-color wp-elements-e501140c9899ad4dd7e6fe8cd80ac031 is-layout-flex wp-container-core-columns-is-layout-f54850f0 wp-block-columns-is-layout-flex\" style=\"padding-top:var(--wp--preset--spacing--50);padding-right:0;padding-bottom:var(--wp--preset--spacing--50);padding-left:0\">\n<div class=\"wp-block-column is-vertically-aligned-top has-nv-text-dark-bg-background-color has-background is-layout-flow wp-block-column-is-layout-flow\" style=\"border-top-left-radius:8px;border-top-right-radius:8px;border-bottom-left-radius:8px;border-bottom-right-radius:8px;padding-top:var(--wp--preset--spacing--40);padding-right:var(--wp--preset--spacing--40);padding-bottom:var(--wp--preset--spacing--40);padding-left:var(--wp--preset--spacing--40);flex-basis:50%\">\n<h3 class=\"wp-block-heading dc-card has-neve-text-color-color has-text-color has-background has-link-color wp-elements-ddf5a393bb59f19cc64e25f71b2ff6d3\" style=\"border-top-left-radius:8px;border-top-right-radius:8px;border-bottom-left-radius:8px;border-bottom-right-radius:8px;border-right-style:none;border-right-width:0px;border-left-color:var(--wp--preset--color--neve-text-color);border-left-width:1px;background-color:#f5f6f79e;padding-top:var(--wp--preset--spacing--50);padding-right:var(--wp--preset--spacing--50);padding-bottom:var(--wp--preset--spacing--50);padding-left:var(--wp--preset--spacing--50);font-size:16px\">Monitoring considered too late (or omitted)<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\" style=\"font-size:16px\"><em><em><em>Especially in larger systems, string monitoring is treated as &#8220;optional,&#8221; even though O&amp;M processes benefit greatly from it.<\/em><\/em><\/em><\/p>\n\n\n\n<p class=\"wp-block-paragraph\" style=\"font-size:16px\"><strong>Typical consequences: <\/strong>Faults are detected late, long troubleshooting in the field, unnecessary downtime.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Better: <\/strong>Define monitoring requirements (string currents, switch status, SPD status) early and integrate them appropriately.<\/p>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-vertically-aligned-top has-nv-text-dark-bg-background-color has-background is-layout-flow wp-block-column-is-layout-flow\" style=\"border-top-left-radius:8px;border-top-right-radius:8px;border-bottom-left-radius:8px;border-bottom-right-radius:8px;padding-top:var(--wp--preset--spacing--40);padding-right:var(--wp--preset--spacing--40);padding-bottom:var(--wp--preset--spacing--40);padding-left:var(--wp--preset--spacing--40)\">\n<h3 class=\"wp-block-heading dc-card has-neve-text-color-color has-text-color has-background has-link-color wp-elements-31723e49e94c7d02d7de23621ee5bdfa\" style=\"border-top-left-radius:8px;border-top-right-radius:8px;border-bottom-left-radius:8px;border-bottom-right-radius:8px;border-right-style:none;border-right-width:0px;border-left-color:var(--wp--preset--color--neve-text-color);border-left-width:1px;background-color:#f5f6f79e;padding-top:var(--wp--preset--spacing--50);padding-right:var(--wp--preset--spacing--50);padding-bottom:var(--wp--preset--spacing--50);padding-left:var(--wp--preset--spacing--50);font-size:16px\">Service accessibility &amp; installation paths underestimated<\/h3>\n\n\n\n<p class=\"wp-block-paragraph\"><em><em>Connection boxes are planned to optimize space, but without sufficient regard for installation, maintenance, component replacement, and safe cable routing.<\/em><\/em><\/p>\n\n\n\n<p class=\"wp-block-paragraph\" style=\"font-size:16px\"><strong>Typical consequences: <\/strong>longer service times, higher costs, unnecessary system downtime.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\"><strong>Better: <\/strong>Plan the layout and installation location so that maintenance and spare part replacement are possible without a &#8220;cable mess.&#8221;<\/p>\n<\/div>\n<\/div>\n\n\n\n<p class=\"has-neve-text-color-color has-text-color has-link-color wp-elements-629ff3d76fcb6c3f502effa8968c5a5a wp-block-paragraph\"><strong>Q3 supports project-related design \u2013 ensuring that the protection concept, component selection, installation, and monitoring fit together from the start.<\/strong><\/p>\n\n\n\n<div class=\"wp-block-cover alignfull\" style=\"padding-top:var(--wp--preset--spacing--50);padding-right:var(--wp--preset--spacing--50);padding-bottom:var(--wp--preset--spacing--50);padding-left:var(--wp--preset--spacing--50)\"><img decoding=\"async\" class=\"wp-block-cover__image-background wp-image-2475 size-full\" alt=\"DC-Anschlusstechnik PV - Generatoranschlussk\u00e4sten - DC Combiner\" src=\"https:\/\/neu.q3-energie.de\/wp-content\/uploads\/2026\/02\/DC-Anschlusstechnik-PV-Generatoranschlusskaesten-DC-Combiner.webp\" data-object-fit=\"cover\" title=\"\"><span aria-hidden=\"true\" class=\"wp-block-cover__background has-nv-text-dark-bg-background-color has-background-dim-90 has-background-dim\"><\/span><div class=\"wp-block-cover__inner-container is-layout-flow wp-block-cover-is-layout-flow\">\n<div style=\"height:100px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<h2 class=\"wp-block-heading alignwide has-neve-text-color-color has-text-color has-link-color wp-elements-a73037c5a3678ac85df91669809a8e3c\" id=\"eignung\">For which systems is our DC connection technology suitable?<\/h2>\n\n\n\n<div style=\"height:10px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<div class=\"wp-block-columns alignwide is-layout-flex wp-container-core-columns-is-layout-8f761849 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<p class=\"has-neve-text-color-color has-text-color has-link-color wp-elements-acfbe03ffce9780a2852c63ddbbf4d70 wp-block-paragraph\" style=\"font-size:16px\"><em>The design of the DC connection technology is project-specific \u2013 tailored to system output, number of strings, system voltage, and monitoring concept.<\/em><\/p>\n<\/div>\n<\/div>\n\n\n\n<div class=\"wp-block-columns alignwide has-neve-link-color-color has-text-color has-link-color wp-elements-d2edf81560a16891e81092e1e30edfcb is-layout-flex wp-container-core-columns-is-layout-98444236 wp-block-columns-is-layout-flex\" style=\"padding-top:var(--wp--preset--spacing--50);padding-right:var(--wp--preset--spacing--50);padding-bottom:var(--wp--preset--spacing--50);padding-left:var(--wp--preset--spacing--50)\">\n<div class=\"wp-block-column is-vertically-aligned-top dc-card has-nv-site-bg-color has-nv-light-bg-background-color has-text-color has-background has-link-color has-small-font-size wp-elements-36e2c05494b454880b88a98b3070fca7 is-layout-flow wp-block-column-is-layout-flow\" style=\"border-top-left-radius:8px;border-top-right-radius:8px;border-bottom-left-radius:8px;border-bottom-right-radius:8px;padding-top:var(--wp--preset--spacing--60);padding-right:var(--wp--preset--spacing--40);padding-bottom:var(--wp--preset--spacing--30);padding-left:var(--wp--preset--spacing--40);flex-basis:50%\">\n<div id=\"wp-block-themeisle-blocks-icon-list-ea05584e\" class=\"wp-block-themeisle-blocks-icon-list\">\n<div id=\"wp-block-themeisle-blocks-icon-list-item-1e983e1a\" class=\"wp-block-themeisle-blocks-icon-list-item\"><i class=\"fas fa-warehouse wp-block-themeisle-blocks-icon-list-item-icon-custom\"><\/i><p class=\"wp-block-themeisle-blocks-icon-list-item-content-custom\"><strong>Commercial &#038; Logistics Roofs<\/strong><\/p><\/div>\n<\/div>\n\n\n\n<p class=\"has-neve-text-color-color has-text-color has-link-color wp-elements-00f065ee9c7af379254bad8387d0214d wp-block-paragraph\" style=\"font-size:16px\"><br>\u25a0 Multiple MPP trackers with high string density<br>\u25a0 System voltages up to 1,500 V DC<br>\u25a0 Focus on cost-effectiveness and fast installation<br>\u25a0 Optionally integrated Type 1+2 surge protection<\/p>\n<\/div>\n\n\n\n<div class=\"wp-block-column dc-card has-nv-light-bg-background-color has-background is-layout-flow wp-block-column-is-layout-flow\" style=\"border-top-left-radius:8px;border-top-right-radius:8px;border-bottom-left-radius:8px;border-bottom-right-radius:8px;padding-top:var(--wp--preset--spacing--60);padding-right:var(--wp--preset--spacing--40);padding-bottom:var(--wp--preset--spacing--30);padding-left:var(--wp--preset--spacing--40);flex-basis:50%\">\n<div id=\"wp-block-themeisle-blocks-icon-list-42efea37\" class=\"wp-block-themeisle-blocks-icon-list\">\n<div id=\"wp-block-themeisle-blocks-icon-list-item-969ac43b\" class=\"wp-block-themeisle-blocks-icon-list-item\"><i class=\"fas fa-mountain wp-block-themeisle-blocks-icon-list-item-icon-custom\"><\/i><p class=\"wp-block-themeisle-blocks-icon-list-item-content-custom\"><strong>Rooftop and Ground-Mounted Systems<\/strong><\/p><\/div>\n<\/div>\n\n\n\n<p class=\"has-neve-text-color-color has-text-color has-link-color wp-elements-549a8f94d897bbdb887694d1f0e4a6e3 wp-block-paragraph\"><br>\u25a0 Adaptation to cable lengths and environmental conditions<br>\u25a0 Consideration of protection class and IP requirements<br>\u25a0 Mechanically robust design for outdoor areas<\/p>\n<\/div>\n<\/div>\n\n\n\n<div class=\"wp-block-columns alignwide has-neve-link-color-color has-text-color has-link-color wp-elements-3ab591ccf9a31c7aa818ea35b3fea40e is-layout-flex wp-container-core-columns-is-layout-98444236 wp-block-columns-is-layout-flex\" style=\"padding-top:var(--wp--preset--spacing--50);padding-right:var(--wp--preset--spacing--50);padding-bottom:var(--wp--preset--spacing--50);padding-left:var(--wp--preset--spacing--50)\">\n<div class=\"wp-block-column is-vertically-aligned-top dc-card has-nv-site-bg-color has-nv-light-bg-background-color has-text-color has-background has-link-color wp-elements-c60a8d46d554ea1e26514c7e89abe55d is-layout-flow wp-block-column-is-layout-flow\" style=\"border-top-left-radius:8px;border-top-right-radius:8px;border-bottom-left-radius:8px;border-bottom-right-radius:8px;padding-top:var(--wp--preset--spacing--60);padding-right:var(--wp--preset--spacing--40);padding-bottom:var(--wp--preset--spacing--30);padding-left:var(--wp--preset--spacing--40);flex-basis:50%\">\n<div id=\"wp-block-themeisle-blocks-icon-list-518b45ce\" class=\"wp-block-themeisle-blocks-icon-list\">\n<div id=\"wp-block-themeisle-blocks-icon-list-item-78136686\" class=\"wp-block-themeisle-blocks-icon-list-item\"><i class=\"fas fa-industry wp-block-themeisle-blocks-icon-list-item-icon-custom\"><\/i><p class=\"wp-block-themeisle-blocks-icon-list-item-content-custom\"><strong>Industrial Plants<\/strong><\/p><\/div>\n<\/div>\n\n\n\n<p class=\"has-neve-text-color-color has-text-color has-link-color wp-elements-abacf397581f29b43007e1b0ddc77247 wp-block-paragraph\"><br>\u25a0 Complex roof structures and different module arrays<br>\u25a0 Increased requirements for grounding and lightning protection<br>\u25a0 Integration into existing monitoring or control systems<\/p>\n<\/div>\n\n\n\n<div class=\"wp-block-column dc-card has-nv-light-bg-background-color has-background is-layout-flow wp-block-column-is-layout-flow\" style=\"border-top-left-radius:8px;border-top-right-radius:8px;border-bottom-left-radius:8px;border-bottom-right-radius:8px;padding-top:var(--wp--preset--spacing--60);padding-right:var(--wp--preset--spacing--40);padding-bottom:var(--wp--preset--spacing--30);padding-left:var(--wp--preset--spacing--40);flex-basis:50%\">\n<div id=\"wp-block-themeisle-blocks-icon-list-235bcc6d\" class=\"wp-block-themeisle-blocks-icon-list\">\n<div id=\"wp-block-themeisle-blocks-icon-list-item-dd433016\" class=\"wp-block-themeisle-blocks-icon-list-item\"><i class=\"fas fa-bolt wp-block-themeisle-blocks-icon-list-item-icon-custom\"><\/i><p class=\"wp-block-themeisle-blocks-icon-list-item-content-custom\"><strong>Systems up to 1,500 V DC<\/strong><\/p><\/div>\n<\/div>\n\n\n\n<p class=\"has-neve-text-color-color has-text-color has-link-color wp-elements-2cee1cef269581a9fc82fae2828409f2 wp-block-paragraph\"><br>\u25a0 Design of all components for 1,500 V DC<br>\u25a0 Standard-compliant switching and isolation devices<br>\u25a0 Consideration of short-circuit currents and reverse current conditions<\/p>\n<\/div>\n<\/div>\n\n\n\n<div class=\"wp-block-columns alignwide has-neve-link-color-color has-text-color has-link-color wp-elements-6c2a5368816df703eee2feea4ca5f4be is-layout-flex wp-container-core-columns-is-layout-98444236 wp-block-columns-is-layout-flex\" style=\"padding-top:var(--wp--preset--spacing--50);padding-right:var(--wp--preset--spacing--50);padding-bottom:var(--wp--preset--spacing--50);padding-left:var(--wp--preset--spacing--50)\">\n<div class=\"wp-block-column is-vertically-aligned-top dc-card has-nv-site-bg-color has-nv-light-bg-background-color has-text-color has-background has-link-color wp-elements-7c86258e9652ca072a828f13655777a1 is-layout-flow wp-block-column-is-layout-flow\" style=\"border-top-left-radius:8px;border-top-right-radius:8px;border-bottom-left-radius:8px;border-bottom-right-radius:8px;padding-top:var(--wp--preset--spacing--60);padding-right:var(--wp--preset--spacing--40);padding-bottom:var(--wp--preset--spacing--30);padding-left:var(--wp--preset--spacing--40);flex-basis:50%\">\n<div id=\"wp-block-themeisle-blocks-icon-list-e088c614\" class=\"wp-block-themeisle-blocks-icon-list\">\n<div id=\"wp-block-themeisle-blocks-icon-list-item-6ac9e463\" class=\"wp-block-themeisle-blocks-icon-list-item\"><i class=\"fas fa-solar-panel wp-block-themeisle-blocks-icon-list-item-icon-custom\"><\/i><p class=\"wp-block-themeisle-blocks-icon-list-item-content-custom\"><strong>PV Power Plants in the MW Range<\/strong><\/p><\/div>\n<\/div>\n\n\n\n<p class=\"has-neve-text-color-color has-text-color has-link-color wp-elements-ec6866164985e68e773d0a5a283f6293 wp-block-paragraph\"><br>\u25a0 High number of strings per inverter<br>\u25a0 DC combiner systems with an extended protection concept<br>\u25a0 Individual string current monitoring for performance analysis<br>\u25a0 Redundant or segmented system structures<\/p>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-vertically-aligned-bottom is-layout-flow wp-block-column-is-layout-flow\" style=\"border-top-left-radius:8px;border-top-right-radius:8px;border-bottom-left-radius:8px;border-bottom-right-radius:8px;padding-top:var(--wp--preset--spacing--40);padding-right:var(--wp--preset--spacing--40);padding-bottom:var(--wp--preset--spacing--40);padding-left:var(--wp--preset--spacing--40);flex-basis:50%\">\n<p class=\"has-neve-text-color-color has-text-color has-link-color wp-elements-4ed9bf170bf35ffd1a3d1707af6350a8 wp-block-paragraph\" style=\"font-size:16px\"><br><br><strong>Scalable from 100 kWp to the MW range \u2013 with adapted protection, monitoring, and switching concepts.<\/strong><\/p>\n\n\n\n<p class=\"dc-anlage-box has-neve-text-color-color has-text-color has-link-color wp-elements-0edac011db0b3be28d9ad9385b954017 wp-block-paragraph\" style=\"font-size:16px\"><br><strong>To match this, we offer both pre-configured standard solutions and fully project-specific string combiner systems.<\/strong><\/p>\n<\/div>\n<\/div>\n<\/div><\/div>\n\n\n\n<div class=\"wp-block-cover alignfull\" style=\"padding-top:var(--wp--preset--spacing--50);padding-right:var(--wp--preset--spacing--50);padding-bottom:var(--wp--preset--spacing--50);padding-left:var(--wp--preset--spacing--50)\"><img decoding=\"async\" class=\"wp-block-cover__image-background wp-image-311 size-full\" alt=\"Q3 ENERGIE - Feuerwehrschalter, DC- und AC-Anschlusstechnik - sichere Anschlusstechnik f\u00fcr Photovoltaik Anlagen\" src=\"https:\/\/neu.q3-energie.de\/wp-content\/uploads\/2026\/01\/Q3-ENERGIE-Feuerwehrschalter-DC-und-AC-Anschlusstechnik-sichere-Anschlusstechnik-fuer-Photovoltaik-Anlagen.webp\" style=\"object-position:12% 45%\" data-object-fit=\"cover\" data-object-position=\"12% 45%\" title=\"\"><span aria-hidden=\"true\" class=\"wp-block-cover__background has-neve-link-color-background-color has-background-dim-90 has-background-dim\"><\/span><div class=\"wp-block-cover__inner-container is-layout-flow wp-block-cover-is-layout-flow\">\n<div style=\"height:20px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<div class=\"wp-block-columns alignwide is-layout-flex wp-container-core-columns-is-layout-8f761849 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\" style=\"padding-top:var(--wp--preset--spacing--50);padding-right:var(--wp--preset--spacing--50);padding-bottom:var(--wp--preset--spacing--50);padding-left:var(--wp--preset--spacing--50);flex-basis:80%\">\n<h2 class=\"wp-block-heading\" style=\"font-size:28px\">FAQ PV String Combiner &#8211; DC Connection Technology<\/h2>\n\n\n\n<div style=\"height:20px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<div id=\"wp-block-themeisle-blocks-accordion-1e20aca1\" class=\"wp-block-themeisle-blocks-accordion icon-first has-icon has-open-icon is-style-default has-light-content-bg\">\n<details class=\"wp-block-themeisle-blocks-accordion-item\"><summary class=\"wp-block-themeisle-blocks-accordion-item__title\"><div>Wann ist eine DC-Combiner-Box notwendig?<\/div><\/summary><div class=\"wp-block-themeisle-blocks-accordion-item__content\">\n<p class=\"wp-block-paragraph\">With a high number of strings or with central inverters in the MW range.<\/p>\n<\/div><\/details>\n\n\n\n<details class=\"wp-block-themeisle-blocks-accordion-item\"><summary class=\"wp-block-themeisle-blocks-accordion-item__title\"><div>Braucht jede PV-Anlage Strangsicherungen?<\/div><\/summary><div class=\"wp-block-themeisle-blocks-accordion-item__content\">\n<p class=\"wp-block-paragraph\">No. The necessity depends on the module short-circuit current, number of strings, and reverse current conditions. <\/p>\n<\/div><\/details>\n\n\n\n<details class=\"wp-block-themeisle-blocks-accordion-item\"><summary class=\"wp-block-themeisle-blocks-accordion-item__title\"><div>Welche Norm gilt f\u00fcr DC-Lasttrennschalter?<\/div><\/summary><div class=\"wp-block-themeisle-blocks-accordion-item__content\">\n<p class=\"wp-block-paragraph\">IEC 60947-3 with DC rating.<\/p>\n<\/div><\/details>\n\n\n\n<details class=\"wp-block-themeisle-blocks-accordion-item\"><summary class=\"wp-block-themeisle-blocks-accordion-item__title\"><div>Was ist der Unterschied zwischen GAK und DC-Combiner?<\/div><\/summary><div class=\"wp-block-themeisle-blocks-accordion-item__content\">\n<p class=\"wp-block-paragraph\">An SCB bundles strings per MPP, while a DC combiner handles extended protection and monitoring functions for large-scale systems.<\/p>\n<\/div><\/details>\n<\/div>\n<\/div>\n<\/div>\n<\/div><\/div>\n\n\n\n<div class=\"wp-block-cover alignfull\" style=\"padding-top:var(--wp--preset--spacing--50);padding-right:var(--wp--preset--spacing--50);padding-bottom:var(--wp--preset--spacing--50);padding-left:var(--wp--preset--spacing--50)\"><img loading=\"lazy\" decoding=\"async\" width=\"1920\" height=\"800\" class=\"wp-block-cover__image-background wp-image-454 size-full\" alt=\"Technische Details\n\" src=\"https:\/\/q3-energie.de\/wp-content\/uploads\/2026\/01\/Background_1920px.webp\" data-object-fit=\"cover\" title=\"\" srcset=\"https:\/\/q3-energie.de\/wp-content\/uploads\/2026\/01\/Background_1920px.webp 1920w, https:\/\/q3-energie.de\/wp-content\/uploads\/2026\/01\/Background_1920px-300x125.webp 300w, https:\/\/q3-energie.de\/wp-content\/uploads\/2026\/01\/Background_1920px-1024x427.webp 1024w, https:\/\/q3-energie.de\/wp-content\/uploads\/2026\/01\/Background_1920px-768x320.webp 768w, https:\/\/q3-energie.de\/wp-content\/uploads\/2026\/01\/Background_1920px-1536x640.webp 1536w\" sizes=\"auto, (max-width: 1920px) 100vw, 1920px\" \/><span aria-hidden=\"true\" class=\"wp-block-cover__background has-neve-text-color-background-color has-background-dim-100 has-background-dim\"><\/span><div class=\"wp-block-cover__inner-container is-layout-flow wp-block-cover-is-layout-flow\">\n<div class=\"wp-block-columns alignwide are-vertically-aligned-bottom has-neve-link-color-color has-text-color has-link-color wp-elements-3bafe091abb1d02fb07fde8d8836615d is-layout-flex wp-container-core-columns-is-layout-0fb72d45 wp-block-columns-is-layout-flex\" style=\"padding-top:0;padding-right:0;padding-bottom:0;padding-left:0\">\n<div class=\"wp-block-column is-vertically-aligned-bottom has-nv-site-bg-color has-text-color has-link-color wp-elements-53bec6916458b8d00c17086c4301cd92 is-layout-flow wp-block-column-is-layout-flow\" style=\"padding-top:0;padding-right:0;padding-bottom:0;padding-left:0;flex-basis:50%\">\n<div style=\"height:100px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<h2 class=\"wp-block-heading has-nv-text-dark-bg-color has-text-color has-link-color wp-elements-fd0878bb687de41d5cdde9387971a4dd\" style=\"font-size:28px\">Normative Requirements for PV String Combiner Boxes<\/h2>\n\n\n\n<div style=\"height:20px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<p class=\"wp-block-paragraph\" style=\"font-size:16px\">Compliance with relevant standards ensures the electrical safety, operational reliability, and normative conformity of PV string combiner systems up to 1,500 V DC.<\/p>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-vertically-aligned-bottom is-layout-flow wp-block-column-is-layout-flow\" style=\"padding-top:0;padding-right:0;padding-bottom:0;padding-left:0;flex-basis:50%\">\n<blockquote class=\"wp-block-quote has-border-color has-nv-text-dark-bg-border-color is-layout-flow wp-block-quote-is-layout-flow\">\n<p class=\"has-nv-text-dark-bg-color has-text-color has-link-color wp-elements-86ce057a812a15732b0214627749c878 wp-block-paragraph\" style=\"font-size:16px\"><em>Q3 already takes these standards into account during the project phase \u2013 from component selection to documented final testing.<\/em><\/p>\n<\/blockquote>\n<\/div>\n<\/div>\n\n\n\n<div class=\"wp-block-columns alignwide are-vertically-aligned-bottom has-neve-link-color-color has-text-color has-link-color wp-elements-197b827b7a6d5d78d98c12785c7bb2da is-layout-flex wp-container-core-columns-is-layout-0e642418 wp-block-columns-is-layout-flex\" style=\"padding-top:var(--wp--preset--spacing--40);padding-right:0;padding-bottom:var(--wp--preset--spacing--40);padding-left:0\">\n<div class=\"wp-block-column is-vertically-aligned-bottom has-nv-site-bg-color has-text-color has-link-color wp-elements-99224877a451f31529c7484b19608bac is-layout-flow wp-block-column-is-layout-flow\" style=\"padding-top:0;padding-right:0;padding-bottom:0;padding-left:0;flex-basis:50%\">\n<div id=\"wp-block-themeisle-blocks-icon-list-281946ff\" class=\"wp-block-themeisle-blocks-icon-list\">\n<div id=\"wp-block-themeisle-blocks-icon-list-item-cced7f1e\" class=\"wp-block-themeisle-blocks-icon-list-item\"><i class=\"fas fa-layer-group wp-block-themeisle-blocks-icon-list-item-icon-custom\"><\/i><p class=\"wp-block-themeisle-blocks-icon-list-item-content-custom\"><strong>EN \/ IEC 61439-1 \/ -2<\/strong><br\/><strong>Low-voltage switchgear and controlgear assemblies<\/strong><\/p><\/div>\n\n\n\n<div id=\"wp-block-themeisle-blocks-icon-list-item-8a22e975\" class=\"wp-block-themeisle-blocks-icon-list-item\"><i class=\"fas fa-toggle-off wp-block-themeisle-blocks-icon-list-item-icon-custom\"><\/i><p class=\"wp-block-themeisle-blocks-icon-list-item-content-custom\"><strong>EN 60947-1 \/ -3 \u2013 <\/strong><br\/><strong>Switchgear and switch-disconnectors<\/strong><\/p><\/div>\n\n\n\n<div id=\"wp-block-themeisle-blocks-icon-list-item-ef74f74e\" class=\"wp-block-themeisle-blocks-icon-list-item\"><i class=\"fas fa-toggle-off wp-block-themeisle-blocks-icon-list-item-icon-custom\"><\/i><p class=\"wp-block-themeisle-blocks-icon-list-item-content-custom\"><strong>IEC 60364-7-712 \u2013 <\/strong><br\/><strong>Electrical installations of buildings \u2013 Photovoltaic (PV) power supply systems<\/strong><\/p><\/div>\n<\/div>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-vertically-aligned-bottom is-layout-flow wp-block-column-is-layout-flow\" style=\"padding-top:0;padding-right:0;padding-bottom:0;padding-left:0;flex-basis:50%\">\n<div id=\"wp-block-themeisle-blocks-icon-list-3c021051\" class=\"wp-block-themeisle-blocks-icon-list\">\n<div id=\"wp-block-themeisle-blocks-icon-list-item-591a38da\" class=\"wp-block-themeisle-blocks-icon-list-item\"><i class=\"fas fa-toggle-off wp-block-themeisle-blocks-icon-list-item-icon-custom\"><\/i><p class=\"wp-block-themeisle-blocks-icon-list-item-content-custom\"><strong>IEC 62548<\/strong> <strong>\u2013 <\/strong><br\/><strong>Design and installation of PV arrays<\/strong><\/p><\/div>\n\n\n\n<div id=\"wp-block-themeisle-blocks-icon-list-item-139e12ca\" class=\"wp-block-themeisle-blocks-icon-list-item\"><i class=\"fas fa-bolt wp-block-themeisle-blocks-icon-list-item-icon-custom\"><\/i><p class=\"wp-block-themeisle-blocks-icon-list-item-content-custom\"><strong>EN 61643-31 \u2013 <\/strong><br\/><strong>Surge protective devices for photovoltaic installations<\/strong><\/p><\/div>\n<\/div>\n<\/div>\n<\/div>\n\n\n\n<div style=\"height:20px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n<\/div><\/div>\n\n\n\n<div style=\"height:100px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<div class=\"wp-block-cover alignfull\" id=\"projektplanung\"><span aria-hidden=\"true\" class=\"wp-block-cover__background has-nv-text-dark-bg-background-color has-background-dim-100 has-background-dim\"><\/span><div class=\"wp-block-cover__inner-container is-layout-constrained wp-block-cover-is-layout-constrained\">\n<h2 class=\"wp-block-heading alignwide has-neve-text-color-color has-text-color has-link-color wp-elements-3d0ca39cc7f7895444fdd75232dd64c3\" style=\"font-size:28px\">Why PV String Combiners from Q3?<\/h2>\n\n\n\n<div class=\"wp-block-columns alignwide has-neve-text-color-color has-text-color has-link-color wp-elements-dd375d1197c2175e1fff0d36cbf69156 is-layout-flex wp-container-core-columns-is-layout-f54850f0 wp-block-columns-is-layout-flex\" style=\"border-top-left-radius:8px;border-top-right-radius:8px;border-bottom-left-radius:8px;border-bottom-right-radius:8px;padding-top:var(--wp--preset--spacing--50);padding-right:0;padding-bottom:var(--wp--preset--spacing--50);padding-left:0\">\n<div class=\"wp-block-column dc-card has-nv-light-bg-background-color has-background is-layout-flow wp-block-column-is-layout-flow\" style=\"padding-top:var(--wp--preset--spacing--40);padding-right:var(--wp--preset--spacing--40);padding-bottom:var(--wp--preset--spacing--40);padding-left:var(--wp--preset--spacing--40)\">\n<div style=\"height:30px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<div id=\"wp-block-themeisle-blocks-font-awesome-icons-5d127027\" class=\"wp-block-themeisle-blocks-font-awesome-icons animated zoomIn delay-500ms\"><span class=\"wp-block-themeisle-blocks-font-awesome-icons-container nan-padding\"><svg viewbox=\"0 0 1800 1800\"><path d=\"M1783.877,760.195L1448.221,519.4c0.936-5.06,1.49-10.252,1.49-15.58V88.032 c0-47.163-38.371-85.533-85.533-85.533h-124.246c-47.162,0-85.533,38.37-85.533,85.533v220.587L918.581,139.452 c-4.537-3.26-9.654-5.051-14.847-5.618c-1.234-0.156-2.483-0.246-3.732-0.255c-1.249,0.009-2.497,0.099-3.732,0.255 c-5.188,0.567-10.309,2.358-14.846,5.618l-865.3,620.743c-14.143,10.142-17.383,29.829-7.236,43.971 c6.155,8.581,15.822,13.149,25.63,13.149c6.361,0,12.78-1.921,18.341-5.913L900.002,203.69l254.396,182.496l63.024,45.211 l132.331,94.932l64.783,46.473l332.604,238.601c5.562,3.991,11.979,5.913,18.341,5.913c9.809,0,19.476-4.568,25.631-13.149 C1801.26,790.027,1798.02,770.337,1783.877,760.195z M1217.423,353.834V88.032c0-12.411,10.099-22.509,22.509-22.509h124.246 c12.41,0,22.509,10.098,22.509,22.509v387.226L1217.423,353.834z\"><\/path><path d=\"M1534.746,800.935c-17.404,0-31.512,14.107-31.512,31.512v894.17c0,1.895-6.37,7.86-17.418,7.86h-353.228 v-548.772c0-17.404-14.107-31.512-31.513-31.512H698.928c-17.404,0-31.512,14.107-31.512,31.512v548.772H314.188 c-11.048,0-17.418-5.966-17.418-7.86v-894.17c0-17.405-14.107-31.512-31.512-31.512c-17.404,0-31.512,14.107-31.512,31.512v894.17 c0,1.169,0.136,2.303,0.197,3.459c2.071,37.474,37.214,67.426,80.245,67.426h384.74c17.405,0,31.512-14.108,31.512-31.513v-548.771 h339.125v548.771c0,17.404,14.107,31.513,31.512,31.513h384.74c43.031,0,78.174-29.952,80.244-67.426 c0.063-1.156,0.198-2.29,0.198-3.459v-894.17C1566.259,815.042,1552.151,800.935,1534.746,800.935z\"><\/path><path d=\"M1073.253,782.176c0-95.411-77.624-173.04-173.04-173.04s-173.04,77.628-173.04,173.04 c0,95.416,77.624,173.04,173.04,173.04S1073.253,877.592,1073.253,782.176z M790.198,782.176 c0-60.663,49.352-110.016,110.016-110.016s110.015,49.353,110.015,110.016c0,60.664-49.352,110.016-110.015,110.016 S790.198,842.84,790.198,782.176z\"><\/path><\/svg><\/span><\/div>\n\n\n\n<div style=\"height:30px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<h2 class=\"wp-block-heading has-text-align-center\" style=\"font-size:16px\"><strong>In-house production since 2010<\/strong><\/h2>\n\n\n\n<p class=\"has-text-align-center wp-block-paragraph\">Development, planning, and assembly at our location in Germany \u2013 with clearly defined testing processes and documented quality assurance.<\/p>\n<\/div>\n\n\n\n<div class=\"wp-block-column dc-card has-nv-light-bg-background-color has-background is-layout-flow wp-block-column-is-layout-flow\" style=\"border-top-left-radius:8px;border-top-right-radius:8px;border-bottom-left-radius:8px;border-bottom-right-radius:8px;padding-top:var(--wp--preset--spacing--40);padding-right:var(--wp--preset--spacing--40);padding-bottom:var(--wp--preset--spacing--40);padding-left:var(--wp--preset--spacing--40)\">\n<div style=\"height:30px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<div id=\"wp-block-themeisle-blocks-font-awesome-icons-18e95918\" class=\"wp-block-themeisle-blocks-font-awesome-icons animated zoomIn delay-500ms\"><span class=\"wp-block-themeisle-blocks-font-awesome-icons-container nan-padding\"><svg viewbox=\"0 0 1800 1800\"><path d=\"M900,1793.016c-2.796,0-5.594-0.375-8.315-1.125c-7.969-2.199-197.36-55.807-388.728-226.607 c-112.377-100.305-201.914-220.375-266.128-356.88c-79.987-170.042-120.543-365.937-120.543-582.248 c0-9.624,4.431-18.711,12.016-24.637L880.752,13.613c11.308-8.837,27.187-8.837,38.496,0l752.451,587.905 c7.584,5.925,12.016,15.013,12.016,24.637c0,216.312-40.559,412.206-120.546,582.248 c-64.212,136.505-153.751,256.575-266.123,356.88c-191.37,170.801-380.764,224.408-388.732,226.607 C905.592,1792.641,902.796,1793.016,900,1793.016z M178.88,641.351c3.271,367.343,125.555,661.791,363.594,875.387 C701.154,1659.123,862.076,1716.81,900,1729.049c37.924-12.239,198.846-69.926,357.525-212.311 c238.039-213.597,360.325-508.044,363.592-875.387L900,77.925L178.88,641.351z\"><\/path><path d=\"M900,1593.533c-2.798,0-5.594-0.375-8.315-1.125c-6.189-1.71-153.319-43.35-301.636-175.734 c-87.095-77.732-156.485-170.791-206.251-276.582c-61.928-131.65-93.328-283.236-93.328-450.545 c0-9.624,4.432-18.711,12.017-24.637L880.752,213.1c11.308-8.834,27.187-8.839,38.496,0l578.266,451.81 c7.585,5.925,12.017,15.013,12.017,24.637c0,167.309-31.399,318.895-93.329,450.545 c-49.762,105.791-119.155,198.85-206.248,276.582c-148.316,132.385-295.446,174.024-301.64,175.734 C905.596,1593.158,902.798,1593.533,900,1593.533z M353.087,704.725c3.256,278.249,96.237,501.402,276.493,663.417 c118.248,106.279,238.227,150.755,270.42,161.38c32.193-10.625,152.172-55.101,270.42-161.38 c180.256-162.016,273.236-385.169,276.495-663.417L900,277.412L353.087,704.725z\"><\/path><\/svg><\/span><\/div>\n\n\n\n<div style=\"height:30px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<h2 class=\"wp-block-heading has-text-align-center\" style=\"font-size:16px\"><strong>Components from renowned manufacturers<\/strong><\/h2>\n\n\n\n<p class=\"has-text-align-center wp-block-paragraph\">Use of tested brand components for switching devices, SPD modules, and connection technology in our DC connection technology.<\/p>\n<\/div>\n\n\n\n<div class=\"wp-block-column dc-card has-nv-light-bg-background-color has-background is-layout-flow wp-block-column-is-layout-flow\" style=\"border-top-left-radius:8px;border-top-right-radius:8px;border-bottom-left-radius:8px;border-bottom-right-radius:8px;padding-top:var(--wp--preset--spacing--40);padding-right:var(--wp--preset--spacing--40);padding-bottom:var(--wp--preset--spacing--40);padding-left:var(--wp--preset--spacing--40)\">\n<div style=\"height:30px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<div id=\"wp-block-themeisle-blocks-font-awesome-icons-b2ebf0ca\" class=\"wp-block-themeisle-blocks-font-awesome-icons animated zoomIn delay-500ms\"><span class=\"wp-block-themeisle-blocks-font-awesome-icons-container nan-padding\"><svg viewbox=\"0 0 1800 1800\"><path d=\"M1711.338,9.595H88.67c-43.603,0-79.074,35.468-79.074,79.061v1622.683 c0,43.594,35.472,79.065,79.074,79.065h1622.667c43.594,0,79.066-35.472,79.066-79.065V88.656 C1790.404,45.063,1754.932,9.595,1711.338,9.595z M88.67,72.128h1622.667c9.117,0,16.532,7.416,16.532,16.528v194.047H72.13V88.656 C72.13,79.544,79.545,72.128,88.67,72.128z M1711.338,1727.871H88.67c-9.125,0-16.541-7.415-16.541-16.532V345.236h1655.74 v1366.103C1727.87,1720.456,1720.455,1727.871,1711.338,1727.871z\"><\/path><path d=\"M207.43,224.637c27.751,0,50.25-22.5,50.25-50.25c0-27.756-22.499-50.25-50.25-50.25 s-50.25,22.495-50.25,50.25C157.18,202.137,179.679,224.637,207.43,224.637z\"><\/path><path d=\"M365.997,224.637c27.751,0,50.25-22.5,50.25-50.25c0-27.756-22.499-50.25-50.25-50.25 s-50.25,22.495-50.25,50.25C315.747,202.137,338.246,224.637,365.997,224.637z\"><\/path><path d=\"M524.563,224.637c27.751,0,50.25-22.5,50.25-50.25c0-27.756-22.5-50.25-50.25-50.25 s-50.25,22.495-50.25,50.25C474.313,202.137,496.813,224.637,524.563,224.637z\"><\/path><path d=\"M1162.234,1090.907l216.864-211.397c8.523-8.307,11.59-20.732,7.913-32.052 c-3.678-11.319-13.461-19.568-25.238-21.28l-299.703-43.55L928.039,511.056c-5.27-10.672-16.14-17.429-28.039-17.429 c-11.901,0-22.77,6.757-28.037,17.429L737.922,782.628l-299.704,43.55c-11.777,1.712-21.561,9.96-25.239,21.28 c-3.679,11.319-0.61,23.745,7.911,32.052l216.867,211.397l-51.192,298.5c-2.011,11.733,2.812,23.585,12.44,30.582 c9.629,6.996,22.399,7.917,32.926,2.381L900,1281.431l268.066,140.939c4.575,2.404,9.57,3.59,14.547,3.59 c6.482,0,12.938-2.015,18.381-5.971c9.632-6.997,14.451-18.853,12.441-30.582L1162.234,1090.907z M914.552,1218.43 c-9.108-4.789-19.993-4.789-29.101,0l-226.542,119.108l43.262-252.258c1.738-10.146-1.623-20.492-8.992-27.677L509.905,878.952 l253.276-36.805c10.184-1.48,18.986-7.875,23.54-17.103L900,595.541l113.268,229.504c4.555,9.228,13.361,15.623,23.542,17.103 l253.278,36.805l-183.273,178.651c-7.371,7.185-10.734,17.535-8.994,27.677l43.271,252.254L914.552,1218.43z\"><\/path><path d=\"M900,1416.294c-17.269,0-31.267,13.998-31.267,31.267v106.119c0,17.269,13.998,31.267,31.267,31.267 c17.27,0,31.267-13.998,31.267-31.267v-106.119C931.267,1430.292,917.27,1416.294,900,1416.294z\"><\/path><path d=\"M1424.206,1150.112l-100.923-32.802c-16.453-5.344-34.072,3.651-39.402,20.069 c-5.339,16.423,3.646,34.063,20.07,39.402l100.923,32.802c3.214,1.043,6.469,1.54,9.671,1.54c13.182,0,25.438-8.401,29.73-21.609 C1449.615,1173.092,1440.629,1155.452,1424.206,1150.112z\"><\/path><path d=\"M1137.244,686.108c5.549,4.033,11.979,5.974,18.352,5.974c9.67,0,19.201-4.469,25.32-12.89l62.381-85.853 c10.15-13.969,7.054-33.524-6.918-43.674c-13.967-10.15-33.518-7.053-43.672,6.916l-62.381,85.853 C1120.176,656.403,1123.272,675.958,1137.244,686.108z\"><\/path><path d=\"M619.075,679.19c6.117,8.421,15.65,12.892,25.321,12.892c6.37,0,12.802-1.941,18.351-5.974 c13.972-10.148,17.068-29.703,6.918-43.672l-62.372-85.853c-10.148-13.965-29.703-17.071-43.672-6.918 c-13.972,10.148-17.068,29.703-6.918,43.672L619.075,679.19z\"><\/path><path d=\"M476.73,1117.311l-100.933,32.793c-16.423,5.335-25.41,22.975-20.073,39.397 c4.292,13.213,16.549,21.614,29.729,21.614c3.202,0,6.458-0.497,9.669-1.54l100.932-32.793 c16.423-5.335,25.411-22.975,20.074-39.397S493.153,1111.976,476.73,1117.311z\"><\/path><\/svg><\/span><\/div>\n\n\n\n<div style=\"height:30px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<h2 class=\"wp-block-heading has-text-align-center\" style=\"font-size:16px\"><strong>Quantity 1 to series production<\/strong><\/h2>\n\n\n\n<p class=\"has-text-align-center wp-block-paragraph\">From project-specific special solutions to cost-effective series production for recurring system concepts.<\/p>\n<\/div>\n<\/div>\n\n\n\n<div class=\"wp-block-columns alignwide has-neve-text-color-color has-text-color has-link-color wp-elements-a6d4c5fcccaadc5c185e52d6bf07c40f is-layout-flex wp-container-core-columns-is-layout-f54850f0 wp-block-columns-is-layout-flex\" style=\"border-top-left-radius:8px;border-top-right-radius:8px;border-bottom-left-radius:8px;border-bottom-right-radius:8px;padding-top:var(--wp--preset--spacing--50);padding-right:0;padding-bottom:var(--wp--preset--spacing--50);padding-left:0\">\n<div class=\"wp-block-column dc-card has-nv-light-bg-background-color has-background is-layout-flow wp-block-column-is-layout-flow\" style=\"padding-top:var(--wp--preset--spacing--40);padding-right:var(--wp--preset--spacing--40);padding-bottom:var(--wp--preset--spacing--40);padding-left:var(--wp--preset--spacing--40)\">\n<div style=\"height:30px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<div id=\"wp-block-themeisle-blocks-font-awesome-icons-fb0debf2\" class=\"wp-block-themeisle-blocks-font-awesome-icons animated zoomIn delay-500ms\"><span class=\"wp-block-themeisle-blocks-font-awesome-icons-container nan-padding\"><svg viewbox=\"0 0 1800 1800\"><path d=\"M1099.021,1358.872c-24.524-10.022-50.942-18.95-78.808-26.835l-51.576,51.575 c152,36.272,245.715,100.936,245.715,161.021c0,89.873-209.631,190.014-510.447,190.014 c-300.812,0-510.448-100.141-510.448-190.014c0-60.081,93.715-124.748,245.711-161.021l-51.575-51.575 c-27.863,7.885-54.28,16.813-78.796,26.835c-114.981,46.993-178.304,112.964-178.304,185.761s63.323,138.769,178.304,185.762 c106.048,43.344,246.366,67.214,395.107,67.214c148.746,0,289.068-23.87,395.116-67.214 c114.977-46.993,178.294-112.965,178.294-185.762S1213.997,1405.865,1099.021,1358.872z\"><\/path><path d=\"M1646.857,537.94L735.386,271.5v-66.372c41.896-13.364,72.331-52.65,72.331-98.919 c0-57.245-46.572-103.816-103.813-103.816S600.092,48.964,600.092,106.208c0,46.269,30.437,85.555,72.332,98.919v1359.694 c0,17.389,14.094,31.482,31.481,31.482c17.388,0,31.481-14.094,31.481-31.482V864.814l911.472-266.441 c13.422-3.922,22.648-16.232,22.648-30.216C1669.506,554.173,1660.279,541.862,1646.857,537.94z M703.904,65.354 c22.526,0,40.85,18.328,40.85,40.854s-18.323,40.849-40.85,40.849s-40.849-18.323-40.849-40.849S681.378,65.354,703.904,65.354z M735.39,799.217V337.098l790.431,231.06L735.39,799.217z\"><\/path><\/svg><\/span><\/div>\n\n\n\n<div style=\"height:30px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<h2 class=\"wp-block-heading has-text-align-center\" style=\"font-size:16px\"><strong><strong>Made in Germany<\/strong><\/strong><\/h2>\n\n\n\n<p class=\"has-text-align-center wp-block-paragraph\">Our DC connection technology is manufactured in Germany \u2013 quality assurance, short coordination paths, fast response times.<\/p>\n<\/div>\n\n\n\n<div class=\"wp-block-column dc-card has-nv-light-bg-background-color has-background is-layout-flow wp-block-column-is-layout-flow\" style=\"border-top-left-radius:8px;border-top-right-radius:8px;border-bottom-left-radius:8px;border-bottom-right-radius:8px;padding-top:var(--wp--preset--spacing--40);padding-right:var(--wp--preset--spacing--40);padding-bottom:var(--wp--preset--spacing--40);padding-left:var(--wp--preset--spacing--40)\">\n<div style=\"height:30px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<div id=\"wp-block-themeisle-blocks-font-awesome-icons-cc2b923d\" class=\"wp-block-themeisle-blocks-font-awesome-icons animated zoomIn delay-500ms\"><span class=\"wp-block-themeisle-blocks-font-awesome-icons-container nan-padding\"><svg viewbox=\"0 0 1800 1800\"><path d=\"M872.831,1326.446c-1.999,0.113-3.853-0.183-5.733-0.53c-6.064-1.076-11.863-3.945-16.53-8.611 l-514.859-514.86c-5.852-5.855-9.138-13.792-9.138-22.068c0-8.275,3.287-16.212,9.142-22.067L455.5,638.535 c12.189-12.185,31.954-12.185,44.126,0l373.109,373.1l727.884-727.89c12.189-12.185,31.949-12.185,44.131,0l119.788,119.784 c5.855,5.851,9.142,13.792,9.142,22.067s-3.286,16.212-9.137,22.063l-869.649,869.645 C889.043,1323.155,881.106,1326.446,872.831,1326.446z M401.905,780.377l470.825,470.83l825.614-825.61l-75.657-75.653 l-727.885,727.889c-12.19,12.186-31.95,12.186-44.13,0L477.563,704.729L401.905,780.377z\"><\/path><path d=\"M1692.376,662.67c22.568,75.209,34.758,154.872,34.758,237.334c0,456.08-371.054,827.129-827.138,827.129 c-456.08,0-827.129-371.05-827.129-827.129c0-456.084,371.049-827.138,827.129-827.138c213.186,0,407.787,81.086,554.605,214.022 l44.161-44.165C1340.604,98.513,1130.391,10.456,899.996,10.456c-490.494,0-889.54,399.051-889.54,889.548 s399.046,889.54,889.54,889.54c490.498,0,889.548-399.042,889.548-889.54c0-100.372-16.734-196.909-47.517-286.985 L1692.376,662.67z\"><\/path><\/svg><\/span><\/div>\n\n\n\n<div style=\"height:30px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<h2 class=\"wp-block-heading has-text-align-center\" style=\"font-size:16px\"><strong><strong>100% tested and documented<\/strong><\/strong><\/h2>\n\n\n\n<p class=\"has-text-align-center wp-block-paragraph\">Electrical testing, visual inspection, and documentation before delivery \u2013 including a test report for every single box.<\/p>\n<\/div>\n\n\n\n<div class=\"wp-block-column dc-card has-nv-light-bg-background-color has-background is-layout-flow wp-block-column-is-layout-flow\" style=\"border-top-left-radius:8px;border-top-right-radius:8px;border-bottom-left-radius:8px;border-bottom-right-radius:8px;padding-top:var(--wp--preset--spacing--40);padding-right:var(--wp--preset--spacing--40);padding-bottom:var(--wp--preset--spacing--40);padding-left:var(--wp--preset--spacing--40)\">\n<div style=\"height:30px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<div id=\"wp-block-themeisle-blocks-font-awesome-icons-760b83b0\" class=\"wp-block-themeisle-blocks-font-awesome-icons animated zoomIn delay-500ms\"><span class=\"wp-block-themeisle-blocks-font-awesome-icons-container nan-padding\"><svg viewbox=\"0 0 1800 1800\"><path d=\"M1541.606,1540.146l0.009-0.008c35.598-35.594,35.598-93.52,0-129.121 c-17.24-17.236-40.178-26.745-64.569-26.745c-24.378,0-47.314,9.509-64.564,26.763c-35.588,35.584-35.588,93.51,0.009,129.104 C1448.096,1575.73,1506.014,1575.73,1541.606,1540.146z M1440.885,1511.743c-9.656-9.655-14.975-22.498-14.975-36.165 c0-13.659,5.318-26.511,14.975-36.167c9.665-9.655,22.512-14.979,36.175-14.979c13.659,0,26.497,5.323,36.161,14.979 c19.938,19.945,19.938,52.387-0.008,72.332C1493.271,1531.689,1460.831,1531.681,1440.885,1511.743z\"><\/path><path d=\"M1700.934,402.736c0.021-0.026,0.047-0.043,0.068-0.065c0.044-0.043,0.083-0.091,0.127-0.134l5.504-5.505 l-0.138-0.139c81.836-87.814,80.038-225.814-5.507-311.356c-42.353-42.357-98.664-65.685-158.565-65.685 c-57.228,0-111.154,21.339-152.792,60.18l-0.134-0.134l-5.511,5.507c-0.043,0.046-0.09,0.085-0.134,0.131 c-0.021,0.021-0.039,0.045-0.061,0.069L66.371,1403.02l0.513,0.513c-7.364,4.749-12.699,12.548-13.98,21.907L9.578,1741.903 c-1.319,9.647,1.95,19.347,8.831,26.232c5.875,5.87,13.807,9.108,22.004,9.108c1.402,0,2.813-0.095,4.224-0.286l316.451-43.338 c9.365-1.276,17.163-6.617,21.912-13.98l0.512,0.513L1700.934,402.736z M1542.423,82.094c43.272,0,83.954,16.852,114.551,47.452 c55.643,55.638,62.276,142.02,19.897,204.983L1451.973,109.64C1478.482,91.724,1509.717,82.094,1542.423,82.094z M1389.497,167.919l229.113,229.112L383.512,1632.129l-86.195-86.19l991.423-991.409l-59.351-59.342l-991.41,991.418 l-83.585-83.586L1389.497,167.919z M76.804,1709.731l35.68-260.604l224.915,224.916L76.804,1709.731z\"><\/path><path d=\"M506.941,804.479l56.789-56.789l-454.446-454.45l185.432-185.437l87.924,87.932l-63.792,63.783 l50.362,50.359l63.792-63.779l51.262,51.258l-63.792,63.788l50.363,50.354l63.797-63.779l51.257,51.267l-94.375,94.353 l50.376,50.363l94.362-94.362l62.502,62.498l-63.792,63.801l50.363,50.354l63.792-63.792l0.043,0.047l56.789-56.789 L323.106,22.622c-15.682-15.686-41.102-15.686-56.784,0L24.102,264.845c-15.687,15.683-15.687,41.107,0,56.789L506.941,804.479z\"><\/path><path d=\"M1778.944,1478.287c-0.726-0.729-1.478-1.424-2.241-2.085l-505.282-505.273l-151.159,151.159l50.259,50.26 l94.371-94.37l428.79,428.782l-185.441,185.432l-479.045-479.041l-56.789,56.798l507.437,507.427 c15.682,15.69,41.102,15.69,56.788,0l242.234-242.213c0.021-0.034,0.048-0.052,0.079-0.086 C1794.63,1519.402,1794.63,1493.969,1778.944,1478.287z\"><\/path><\/svg><\/span><\/div>\n\n\n\n<div style=\"height:30px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<h2 class=\"wp-block-heading has-text-align-center\" style=\"font-size:16px\"><strong><strong>Project-related planning<\/strong><\/strong><\/h2>\n\n\n\n<p class=\"has-text-align-center wp-block-paragraph\">Early coordination reduces over-dimensioning, saves material usage, and ensures standard-compliant integration of our DC connection technology.<\/p>\n<\/div>\n<\/div>\n<\/div><\/div>\n\n\n\n<p class=\"has-neve-text-color-color has-text-color has-link-color has-medium-font-size wp-elements-d8880b7aaf1f6ce913be6e1f9b8f27d9 wp-block-paragraph\"><strong>Q3 is not a catalog provider, but a development partner for PV string combiners and DC connection technology in the commercial and power plant sectors.<\/strong><\/p>\n\n\n\n<div style=\"height:50px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<div class=\"wp-block-cover alignfull\" style=\"padding-top:var(--wp--preset--spacing--50);padding-right:var(--wp--preset--spacing--50);padding-bottom:var(--wp--preset--spacing--50);padding-left:var(--wp--preset--spacing--50)\"><img decoding=\"async\" class=\"wp-block-cover__image-background wp-image-311 size-full\" alt=\"Q3 ENERGIE - Feuerwehrschalter, DC- und AC-Anschlusstechnik - sichere Anschlusstechnik f\u00fcr Photovoltaik Anlagen\" src=\"https:\/\/neu.q3-energie.de\/wp-content\/uploads\/2026\/01\/Q3-ENERGIE-Feuerwehrschalter-DC-und-AC-Anschlusstechnik-sichere-Anschlusstechnik-fuer-Photovoltaik-Anlagen.webp\" style=\"object-position:12% 45%\" data-object-fit=\"cover\" data-object-position=\"12% 45%\" title=\"\"><span aria-hidden=\"true\" class=\"wp-block-cover__background has-neve-text-color-background-color has-background-dim-100 has-background-dim\"><\/span><div class=\"wp-block-cover__inner-container is-layout-flow wp-block-cover-is-layout-flow\">\n<div style=\"height:100px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<h2 class=\"wp-block-heading alignwide has-nv-text-dark-bg-color has-text-color has-link-color wp-elements-397f714f5a6bce90f2e0505df9a4ad61\" id=\"sicherheit\" style=\"font-size:28px\">Why is DC connection technology safety-critical?<\/h2>\n\n\n\n<div style=\"height:30px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<div class=\"wp-block-columns alignwide has-nv-text-dark-bg-color has-text-color has-link-color wp-elements-14363f3666761cf12093cdd9d3bc7f76 is-layout-flex wp-container-core-columns-is-layout-0fb72d45 wp-block-columns-is-layout-flex\" style=\"padding-top:0;padding-right:0;padding-bottom:0;padding-left:0\">\n<div class=\"wp-block-column is-vertically-aligned-top has-nv-site-bg-color has-text-color has-background has-link-color wp-elements-0de8a3f58c2f0c6e1a90ff10a42baedc is-layout-flow wp-block-column-is-layout-flow\" style=\"border-top-left-radius:8px;border-top-right-radius:8px;border-bottom-left-radius:8px;border-bottom-right-radius:8px;border-left-color:var(--nv-text-dark-bg);border-left-width:1px;background-color:#212121;padding-top:var(--wp--preset--spacing--40);padding-right:var(--wp--preset--spacing--40);padding-bottom:var(--wp--preset--spacing--40);padding-left:var(--wp--preset--spacing--40);flex-basis:50%\">\n<p class=\"dc-card wp-block-paragraph\" style=\"font-size:16px\">Photovoltaic systems in the commercial and power plant sectors operate with DC voltages up to 1,500 V DC and high short-circuit currents.<br>Unlike AC systems, DC systems feature:<br><br><strong>\u25a0 no natural zero crossings<br>\u25a0 higher arc stability<br>\u25a0 increased requirements for switching and isolation devices<\/strong><\/p>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-vertically-aligned-top dc-card has-background is-layout-flow wp-block-column-is-layout-flow\" style=\"border-top-left-radius:8px;border-top-right-radius:8px;border-bottom-left-radius:8px;border-bottom-right-radius:8px;border-left-color:var(--nv-text-dark-bg);border-left-width:1px;background-color:#212121;padding-top:var(--wp--preset--spacing--40);padding-right:var(--wp--preset--spacing--40);padding-bottom:var(--wp--preset--spacing--40);padding-left:var(--wp--preset--spacing--40);flex-basis:50%\">\n<p class=\"has-nv-text-dark-bg-color has-text-color has-link-color wp-elements-cf91293af4e514ff45ba2c3c45a9925e wp-block-paragraph\" style=\"border-top-left-radius:0px;border-top-right-radius:0px;border-bottom-left-radius:0px;border-bottom-right-radius:0px;border-left-style:none;border-left-width:0px;font-size:16px\">A standard-compliant string combiner technology ensures <br>that:<br><br><strong>\u25a0 parallel connections are correctly protected<br>\u25a0 surge protection is appropriately dimensioned<br>\u25a0 defined shutdown and isolation options are available<\/strong><br><strong>\u25a0 status and error messages are reliably recorded<\/strong><br><\/p>\n<\/div>\n<\/div>\n\n\n\n<div class=\"wp-block-columns alignwide has-nv-text-dark-bg-color has-text-color has-link-color wp-elements-67de4c371199e1c351e00d7d44b9f5fe is-layout-flex wp-container-core-columns-is-layout-0fb72d45 wp-block-columns-is-layout-flex\" style=\"padding-top:0;padding-right:0;padding-bottom:0;padding-left:0\">\n<div class=\"wp-block-column is-vertically-aligned-top has-nv-site-bg-color has-text-color has-background has-link-color wp-elements-d93da55c1f92f37315bd530d5554cca8 is-layout-flow wp-block-column-is-layout-flow\" style=\"border-top-left-radius:8px;border-top-right-radius:8px;border-bottom-left-radius:8px;border-bottom-right-radius:8px;border-left-color:var(--nv-text-dark-bg);border-left-width:1px;background-color:#212121;padding-top:var(--wp--preset--spacing--40);padding-right:var(--wp--preset--spacing--40);padding-bottom:var(--wp--preset--spacing--40);padding-left:var(--wp--preset--spacing--40);flex-basis:50%\">\n<p class=\"dc-card wp-block-paragraph\" style=\"font-size:16px\">Faulty or insufficiently dimensioned DC connection technology can lead to:<br><br><strong>\u25a0 thermal overload<br>\u25a0 contact problems<br>\u25a0 reverse currents between strings<\/strong><br><strong>\u25a0 damage to inverters<\/strong><br><strong>\u25a0 increased maintenance effort<\/strong>.<\/p>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-vertically-aligned-bottom is-layout-flow wp-block-column-is-layout-flow\" style=\"padding-top:var(--wp--preset--spacing--40);padding-right:var(--wp--preset--spacing--40);padding-bottom:var(--wp--preset--spacing--40);padding-left:var(--wp--preset--spacing--40);flex-basis:50%\">\n<p class=\"has-nv-text-dark-bg-color has-text-color has-link-color wp-elements-06d6a1222fcdce244c50c8e6771e6a1b wp-block-paragraph\" style=\"font-size:16px\"><strong>Especially in large-scale systems, the quality of the DC connection technology determines operational safety and long-term yield stability.<\/strong><\/p>\n<\/div>\n<\/div>\n\n\n\n<div style=\"height:30px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n<\/div><\/div>\n\n\n\n<div class=\"wp-block-cover alignfull\" style=\"padding-top:var(--wp--preset--spacing--50);padding-right:var(--wp--preset--spacing--50);padding-bottom:var(--wp--preset--spacing--50);padding-left:var(--wp--preset--spacing--50)\"><img decoding=\"async\" class=\"wp-block-cover__image-background wp-image-2475 size-full\" alt=\"DC-Anschlusstechnik PV - Generatoranschlussk\u00e4sten - DC Combiner\" src=\"https:\/\/neu.q3-energie.de\/wp-content\/uploads\/2026\/02\/DC-Anschlusstechnik-PV-Generatoranschlusskaesten-DC-Combiner.webp\" data-object-fit=\"cover\" title=\"\"><span aria-hidden=\"true\" class=\"wp-block-cover__background has-nv-text-dark-bg-background-color has-background-dim-100 has-background-dim\"><\/span><div class=\"wp-block-cover__inner-container is-layout-flow wp-block-cover-is-layout-flow\">\n<div style=\"height:100px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<h2 class=\"wp-block-heading has-text-align-left alignwide has-neve-text-color-color has-text-color has-link-color wp-elements-f5946a161ca5c05589487ec9b9a65039\" id=\"\u00fcberblick\" style=\"font-size:28px\">Our PV String Combiner Boxes at a Glance<\/h2>\n\n\n\n<div class=\"wp-block-columns alignwide is-layout-flex wp-container-core-columns-is-layout-8f761849 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<p class=\"has-neve-text-color-color has-text-color has-link-color wp-elements-0fccdcac30f3c4b7d31e18990664c89c wp-block-paragraph\" style=\"font-size:16px\">Q3 develops and manufactures DC connection technology for photovoltaic systems up to 1,500 V DC \u2013 from cost-effective standard solutions to project-specific large-scale systems. Depending on the system layout, number of strings, and protection concept, string combiner boxes, string boxes, or DC combiner systems are used. <\/p>\n<\/div>\n<\/div>\n\n\n\n<div class=\"wp-block-columns alignwide are-vertically-aligned-top has-neve-link-color-color has-text-color has-link-color has-medium-font-size wp-elements-6e65b1810c9b059ef8187078fd5edd40 wp-container-content-9cfa9a5a is-layout-flex wp-container-core-columns-is-layout-5e6aac66 wp-block-columns-is-layout-flex\" style=\"padding-top:var(--wp--preset--spacing--40);padding-right:var(--wp--preset--spacing--40);padding-bottom:var(--wp--preset--spacing--40);padding-left:var(--wp--preset--spacing--40)\">\n<div class=\"wp-block-column is-vertically-aligned-top dc-card has-nv-light-bg-background-color has-background has-medium-font-size is-layout-flow wp-block-column-is-layout-flow\" style=\"border-top-left-radius:8px;border-top-right-radius:8px;border-bottom-left-radius:8px;border-bottom-right-radius:8px;padding-top:var(--wp--preset--spacing--50);padding-right:var(--wp--preset--spacing--50);padding-bottom:var(--wp--preset--spacing--50);padding-left:var(--wp--preset--spacing--50);flex-basis:50%\">\n<div class=\"wp-block-group\"><div class=\"wp-block-group__inner-container is-layout-constrained wp-block-group-is-layout-constrained\">\n<div class=\"wp-block-group is-nowrap is-layout-flex wp-container-core-group-is-layout-f221bfd0 wp-block-group-is-layout-flex\">\n<div id=\"wp-block-themeisle-blocks-font-awesome-icons-99531212\" class=\"wp-block-themeisle-blocks-font-awesome-icons\"><span class=\"wp-block-themeisle-blocks-font-awesome-icons-container\"><i class=\"fas fa-box\"><\/i><\/span><\/div>\n\n\n\n<h3 class=\"wp-block-heading has-neve-text-color-color has-text-color has-link-color wp-elements-bfedb54a8b86b09e4a410715a3d9c52e\" style=\"font-size:20px\"><br>PV String Combiner Box (SCB)<\/h3>\n<\/div>\n<\/div><\/div>\n\n\n\n<p class=\"has-neve-text-color-color has-text-color has-link-color wp-elements-8f024350bca0cf18f78bab5e9fc88bdd wp-block-paragraph\" style=\"font-size:16px\"><br><em>Individually configured string combiner boxes for standard-compliant parallel connection of multiple PV strings per MPP tracker.<\/em><br><br><strong>Typical functions (depending on the version):<\/strong><br><br><strong>\u25a0<\/strong> String fuses or blocking diodes for reverse current limitation<br><strong>\u25a0<\/strong> DC surge protection (optional, e.g., Type 1+2)<br><strong>\u25a0<\/strong> DC switch-disconnector \/ load-break switch<br><strong>\u25a0<\/strong> Status messages (e.g., SPD remote signaling contact)<br><strong>\u25a0<\/strong> Optional: Monitoring on a string basis<br><br><em>Area of application: Commercial, industrial, large rooftop systems, ground-mounted.<\/em><br><br><\/p>\n\n\n\n<div class=\"wp-block-buttons is-layout-flex wp-block-buttons-is-layout-flex\">\n<div class=\"wp-block-button has-custom-width wp-block-button__width-100 is-style-secondary dc-card\"><a class=\"wp-block-button__link has-neve-text-color-color has-text-color has-link-color has-medium-font-size has-custom-font-size wp-element-button\" href=\"https:\/\/neu.q3-energie.de\/produkte\/generatoranschlusskasten\/\" style=\"border-width:1px\">More about PV String Combiner Boxes (SCB) \u2192<\/a><\/div>\n<\/div>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-vertically-aligned-top dc-card has-nv-light-bg-background-color has-background has-medium-font-size is-layout-flow wp-block-column-is-layout-flow\" style=\"border-top-left-radius:8px;border-top-right-radius:8px;border-bottom-left-radius:8px;border-bottom-right-radius:8px;padding-top:var(--wp--preset--spacing--50);padding-right:var(--wp--preset--spacing--50);padding-bottom:var(--wp--preset--spacing--50);padding-left:var(--wp--preset--spacing--50);flex-basis:50%\">\n<div class=\"wp-block-group\"><div class=\"wp-block-group__inner-container is-layout-constrained wp-block-group-is-layout-constrained\">\n<div class=\"wp-block-group is-nowrap is-layout-flex wp-container-core-group-is-layout-f221bfd0 wp-block-group-is-layout-flex\">\n<div id=\"wp-block-themeisle-blocks-font-awesome-icons-f8b5a60a\" class=\"wp-block-themeisle-blocks-font-awesome-icons\"><span class=\"wp-block-themeisle-blocks-font-awesome-icons-container\"><i class=\"fas fa-layer-group\"><\/i><\/span><\/div>\n\n\n\n<h3 class=\"wp-block-heading has-neve-text-color-color has-text-color has-link-color wp-elements-a363b09294f0d32825695f97fb04623c\" style=\"font-size:20px\"><br>SCB LITE \u2013 Standard solution with short delivery time<\/h3>\n<\/div>\n\n\n\n<p class=\"has-neve-text-color-color has-text-color has-link-color wp-elements-0cdcd83f02bd541847605a9df5d4bc01 wp-block-paragraph\" style=\"font-size:16px\"><br><em>SCB LITE is the cost-effective standard version for recurring system concepts in DC connection technology. Pre-configured designs reduce engineering effort and enable fast availability \u2013 ideal for installation companies and wholesalers. <\/em><\/p>\n\n\n\n<p class=\"has-neve-text-color-color has-text-color has-link-color wp-elements-320928be7726912bcf825d605f4d1323 wp-block-paragraph\" style=\"font-size:16px\"><strong>Typical features:<\/strong><br><br><strong>\u25a0<\/strong> Standardized design<br><strong>\u25a0<\/strong> Focus on cost-effectiveness<br><strong>\u25a0<\/strong> Optionally integrated surge protection<br><strong>\u25a0<\/strong> Suitable for recurring string\/MPP structures<br><br><br><\/p>\n\n\n\n<div class=\"wp-block-buttons is-layout-flex wp-block-buttons-is-layout-flex\">\n<div class=\"wp-block-button has-custom-width wp-block-button__width-100 is-style-secondary dc-card\"><a class=\"wp-block-button__link has-neve-text-color-color has-text-color has-link-color has-medium-font-size has-custom-font-size wp-element-button\" href=\"https:\/\/neu.q3-energie.de\/produkte\/gak-lite\/\" style=\"border-width:1px\">Details on SCB LITE \u2192  <\/a><\/div>\n<\/div>\n<\/div><\/div>\n<\/div>\n<\/div>\n\n\n\n<div class=\"wp-block-columns alignwide are-vertically-aligned-top has-neve-link-color-color has-text-color has-link-color has-medium-font-size wp-elements-1e6a71cf84bc6dac984d16fde412f6cb wp-container-content-9cfa9a5a is-layout-flex wp-container-core-columns-is-layout-5e6aac66 wp-block-columns-is-layout-flex\" style=\"padding-top:var(--wp--preset--spacing--40);padding-right:var(--wp--preset--spacing--40);padding-bottom:var(--wp--preset--spacing--40);padding-left:var(--wp--preset--spacing--40)\">\n<div class=\"wp-block-column is-vertically-aligned-top dc-card has-nv-light-bg-background-color has-background has-medium-font-size is-layout-flow wp-block-column-is-layout-flow\" style=\"border-top-left-radius:8px;border-top-right-radius:8px;border-bottom-left-radius:8px;border-bottom-right-radius:8px;padding-top:var(--wp--preset--spacing--50);padding-right:var(--wp--preset--spacing--50);padding-bottom:var(--wp--preset--spacing--50);padding-left:var(--wp--preset--spacing--50);flex-basis:50%\">\n<div class=\"wp-block-group\"><div class=\"wp-block-group__inner-container is-layout-constrained wp-block-group-is-layout-constrained\">\n<div class=\"wp-block-group is-nowrap is-layout-flex wp-container-core-group-is-layout-f221bfd0 wp-block-group-is-layout-flex\">\n<div id=\"wp-block-themeisle-blocks-font-awesome-icons-7dd87908\" class=\"wp-block-themeisle-blocks-font-awesome-icons\"><span class=\"wp-block-themeisle-blocks-font-awesome-icons-container\"><i class=\"fas fa-bolt\"><\/i><\/span><\/div>\n\n\n\n<h3 class=\"wp-block-heading has-neve-text-color-color has-text-color has-link-color wp-elements-c4784c08f1a1cbf83243ebfabe4adbf9\" style=\"font-size:20px\"><br>DC Combiner &#8220;Super Multi Box&#8221; for PV Power Plants<\/h3>\n<\/div>\n\n\n\n<p class=\"has-neve-text-color-color has-text-color has-link-color wp-elements-e2f09d690ece9a2e2d2c7a94a378067e wp-block-paragraph\" style=\"font-size:16px\"><br><em>The Super Multi Box is a DC combiner system for large-scale systems with an extended protection and monitoring concept.  <\/em><br><em>It is particularly suitable for systems with a high number of strings per inverter and clear segmentation in the field.<\/em><br><br><strong>Special features:<\/strong><br><br><strong>\u25a0<\/strong> Patented fault discrimination for precise identification of string faults<br><strong>\u25a0<\/strong> Integration of switching and isolation functions (including firefighter switches)<br><strong>\u25a0<\/strong> String monitoring<br><strong>\u25a0<\/strong> Bundling and protection of many strings<br><br><em>For PV power plants in the MW range and demanding O&amp;M concepts<\/em><br><\/p>\n<\/div><\/div>\n\n\n\n<div class=\"wp-block-buttons is-layout-flex wp-block-buttons-is-layout-flex\">\n<div class=\"wp-block-button has-custom-width wp-block-button__width-100 is-style-secondary dc-card\"><a class=\"wp-block-button__link has-neve-text-color-color has-text-color has-link-color has-medium-font-size has-custom-font-size wp-element-button\" href=\"https:\/\/neu.q3-energie.de\/produkte\/dc-combiner-super-multi-box\/\" style=\"border-width:1px\">To the Super Multi Box \u2192<\/a><\/div>\n<\/div>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-vertically-aligned-top dc-card has-nv-light-bg-background-color has-background has-medium-font-size is-layout-flow wp-block-column-is-layout-flow\" style=\"border-top-left-radius:8px;border-top-right-radius:8px;border-bottom-left-radius:8px;border-bottom-right-radius:8px;padding-top:var(--wp--preset--spacing--50);padding-right:var(--wp--preset--spacing--50);padding-bottom:var(--wp--preset--spacing--50);padding-left:var(--wp--preset--spacing--50);flex-basis:50%\">\n<div class=\"wp-block-group\"><div class=\"wp-block-group__inner-container is-layout-constrained wp-block-group-is-layout-constrained\">\n<div class=\"wp-block-group is-nowrap is-layout-flex wp-container-core-group-is-layout-f221bfd0 wp-block-group-is-layout-flex\">\n<div id=\"wp-block-themeisle-blocks-font-awesome-icons-aa9e96c5\" class=\"wp-block-themeisle-blocks-font-awesome-icons\"><span class=\"wp-block-themeisle-blocks-font-awesome-icons-container\"><i class=\"fas fa-sliders-h\"><\/i><\/span><\/div>\n\n\n\n<h3 class=\"wp-block-heading has-neve-text-color-color has-text-color has-link-color wp-elements-4314b17b3714d38603732f453221cbff\" style=\"font-size:20px\"><br>Customized DC solutions \u2013 &#8220;We build your box&#8221;<\/h3>\n<\/div>\n\n\n\n<p class=\"has-neve-text-color-color has-text-color has-link-color wp-elements-48bf692d89ea7f48de74f3bbf68cc675 wp-block-paragraph\" style=\"font-size:16px\"><br><em>If standard doesn&#8217;t fit, Q3 develops project-specific DC connection solutions \u2013 starting from quantity 1.<\/em><br><em><br>Typical reasons include special installation situations, high currents, special connector systems, monitoring requirements, or safety concepts (e.g., firefighter switches).<\/em><br><br><\/p>\n\n\n\n<p class=\"has-neve-text-color-color has-text-color has-link-color wp-elements-7b051b187b90b2dc82590ecc7e913847 wp-block-paragraph\" style=\"font-size:16px\"><strong>Typical adaptations:<\/strong><br><br><strong>\u25a0<\/strong> Special enclosures, protection classes, cable paths<br><strong>\u25a0<\/strong> Individual SPD and fuse concept<br><strong>\u25a0<\/strong> Interfaces to monitoring\/control technology<br><strong>\u25a0<\/strong> Quantity 1 feasible<br><br><\/p>\n\n\n\n<div class=\"wp-block-buttons is-layout-flex wp-block-buttons-is-layout-flex\">\n<div class=\"wp-block-button has-custom-width wp-block-button__width-100 is-style-secondary dc-card\"><a class=\"wp-block-button__link has-neve-text-color-color has-text-color has-link-color has-medium-font-size has-custom-font-size wp-element-button\" href=\"https:\/\/neu.q3-energie.de\/produkte\/projektanfrage\/generatoranschlusskasten-gak\/\" style=\"border-width:1px\">Request a project solution \u2192<\/a><\/div>\n<\/div>\n<\/div><\/div>\n<\/div>\n<\/div>\n\n\n\n<div class=\"wp-block-columns alignwide is-layout-flex wp-container-core-columns-is-layout-8f761849 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<p class=\"has-neve-text-color-color has-text-color has-link-color wp-elements-ab8abb111ae65772e0feba7db89e1f56 wp-block-paragraph\" style=\"font-size:16px\"><strong>Are you unsure which DC connection technology best fits your system?<br>We support you with the design \u2013 tailored to the module and inverter concept, number of strings, and protection requirements.<\/strong><\/p>\n<\/div>\n<\/div>\n<\/div><\/div>\n\n\n\n<div class=\"wp-block-cover alignfull\"><span aria-hidden=\"true\" class=\"wp-block-cover__background has-neve-text-color-background-color has-background-dim-100 has-background-dim\"><\/span><div class=\"wp-block-cover__inner-container is-layout-constrained wp-block-cover-is-layout-constrained\">\n<div class=\"wp-block-columns alignwide has-neve-text-color-background-color has-background is-layout-flex wp-container-core-columns-is-layout-f54850f0 wp-block-columns-is-layout-flex\" style=\"padding-top:var(--wp--preset--spacing--50);padding-right:0;padding-bottom:var(--wp--preset--spacing--50);padding-left:0\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\" style=\"padding-top:var(--wp--preset--spacing--40);padding-right:0;padding-bottom:var(--wp--preset--spacing--40);padding-left:0\">\n<div style=\"height:50px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<h2 class=\"wp-block-heading has-nv-text-dark-bg-color has-text-color has-link-color wp-elements-0b48378432e64c3d741c6fddc1dc2cb5\" style=\"font-size:28px\">Differentiation from AC connection technology \u2013 technically speaking<\/h2>\n\n\n\n<div style=\"height:30px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<p class=\"has-nv-text-dark-bg-color has-text-color has-link-color wp-elements-3b3cd4dfe7f66f7ec61e4a84dfaf922e wp-block-paragraph\" style=\"font-size:16px\">While AC connection technology works in the familiar low-voltage grid with sinusoidal alternating current, the DC side of a PV system places significantly higher demands on protection and switching technology. The differences are not cosmetic \u2013 they are physical. <\/p>\n\n\n\n<div style=\"height:30px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<div id=\"wp-block-themeisle-blocks-icon-list-3b1c8cc4\" class=\"wp-block-themeisle-blocks-icon-list\">\n<div id=\"wp-block-themeisle-blocks-icon-list-item-983afde8\" class=\"wp-block-themeisle-blocks-icon-list-item animated fadeInLeft\"><i class=\"fas fa-shield-alt wp-block-themeisle-blocks-icon-list-item-icon-custom\"><\/i><p class=\"wp-block-themeisle-blocks-icon-list-item-content-custom\"><strong>Protection concepts \u2013 DC is not &#8220;AC without N&#8221;<\/strong><\/p><\/div>\n\n\n\n<div id=\"wp-block-themeisle-blocks-icon-list-item-d30e2db5\" class=\"wp-block-themeisle-blocks-icon-list-item animated fadeInLeft delay-1s\"><i class=\"fas fa-bolt wp-block-themeisle-blocks-icon-list-item-icon-custom\"><\/i><p class=\"wp-block-themeisle-blocks-icon-list-item-content-custom\"><strong>Current and voltage ranges \u2013 permanently energized<\/strong><\/p><\/div>\n\n\n\n<div id=\"wp-block-themeisle-blocks-icon-list-item-63c4fa00\" class=\"wp-block-themeisle-blocks-icon-list-item animated fadeInLeft delay-2s\"><i class=\"fas fa-file-pdf wp-block-themeisle-blocks-icon-list-item-icon-custom\"><\/i><p class=\"wp-block-themeisle-blocks-icon-list-item-content-custom\"><strong>Normative requirements \u2013 specific to PV generators<\/strong><\/p><\/div>\n<\/div>\n\n\n\n<div style=\"height:50px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<p class=\"has-nv-text-dark-bg-color has-text-color has-link-color wp-elements-3d3d86875f6abb60e665b195fc510a81 wp-block-paragraph\" style=\"font-size:16px\">DC and AC connection technology follow different physical laws \u2013 only the correct separation of the concepts creates a safe overall system.<\/p>\n\n\n\n<div style=\"height:30px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-vertically-aligned-bottom is-layout-flow wp-block-column-is-layout-flow\" style=\"padding-top:var(--wp--preset--spacing--40);padding-right:var(--wp--preset--spacing--50);padding-bottom:var(--wp--preset--spacing--40);padding-left:var(--wp--preset--spacing--50)\">\n<p class=\"dc-card has-nv-text-dark-bg-color has-text-color has-background has-link-color wp-elements-ae21b27ca5a2faf41d2004fe43ac38f0 wp-block-paragraph\" style=\"border-top-left-radius:8px;border-top-right-radius:8px;border-bottom-left-radius:8px;border-bottom-right-radius:8px;border-left-color:var(--nv-site-bg);border-left-width:1px;background-color:#222222;font-size:16px\">Anyone who treats DC like an &#8220;extended AC distribution&#8221; risks:<br><br><strong>\u25a0 over-dimensioning or incorrect protection<\/strong><br><strong>\u25a0 unnecessary material usage<\/strong><br><strong>\u25a0 thermal stress in the event of a fault<\/strong><br><strong>\u25a0 normatively vulnerable designs<\/strong><\/p>\n<\/div>\n<\/div>\n<\/div><\/div>\n\n\n\n<div style=\"height:100px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<h2 class=\"wp-block-heading has-neve-text-color-color has-text-color has-link-color wp-elements-20aa0602fabab149f34d650d2b24116b\" style=\"font-size:28px\">Project Inquiry PV String Combiner<\/h2>\n\n\n\n<div class=\"wp-block-columns has-neve-text-color-color has-text-color has-link-color wp-elements-fbbd9b39a60409a07226dfab4935e7d3 is-layout-flex wp-container-core-columns-is-layout-0fb72d45 wp-block-columns-is-layout-flex\" style=\"padding-top:0;padding-right:0;padding-bottom:0;padding-left:0\">\n<div class=\"wp-block-column is-vertically-aligned-bottom has-neve-text-color-color has-text-color has-link-color wp-elements-05e931f026d1ec498c86f01259d4d352 is-layout-flow wp-block-column-is-layout-flow\" style=\"padding-top:var(--wp--preset--spacing--50);padding-right:0;padding-bottom:var(--wp--preset--spacing--50);padding-left:0;flex-basis:50%\">\n<p class=\"wp-block-paragraph\" style=\"font-size:16px\"><strong>Would you like to design a project-specific DC connection box or a string combiner box (SCB), have protection concepts checked, or define the appropriate configuration for your photovoltaic system?<\/strong> <br><br><br>Using the following inquiry forms, we record all relevant project data in a structured and traceable manner.  <\/p>\n\n\n\n<div class=\"wp-block-buttons alignwide is-content-justification-center is-layout-flex wp-container-core-buttons-is-layout-fb00162f wp-block-buttons-is-layout-flex\" style=\"padding-top:var(--wp--preset--spacing--50);padding-right:var(--wp--preset--spacing--80);padding-bottom:var(--wp--preset--spacing--50);padding-left:var(--wp--preset--spacing--80)\">\n<div class=\"wp-block-button has-custom-width wp-block-button__width-50 is-style- dc-card is-style-secondary\"><a class=\"wp-block-button__link has-neve-text-color-color has-text-color has-link-color has-medium-font-size has-custom-font-size wp-element-button\" style=\"border-width:1px;border-top-left-radius:8px;border-top-right-radius:8px;border-bottom-left-radius:8px;border-bottom-right-radius:8px\">Start PV string combiner project inquiry \u2192<\/a><\/div>\n<\/div>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-vertically-aligned-bottom is-layout-flow wp-block-column-is-layout-flow\" style=\"padding-top:var(--wp--preset--spacing--50);padding-right:0;padding-bottom:var(--wp--preset--spacing--50);padding-left:0;flex-basis:50%\">\n<p class=\"has-neve-text-color-color has-text-color has-link-color wp-elements-cdb94a56ff46e2491810028923bc04b8 wp-block-paragraph\" style=\"font-size:16px\"><em>You are welcome to send string plans, module data, inverter types, short-circuit currents (Isc), system voltage, or monitoring requirements directly.<\/em><\/p>\n\n\n\n<p class=\"has-neve-text-color-color has-text-color has-link-color wp-elements-b7a5652e681eac3deb2fee3e7e66c4dc wp-block-paragraph\" style=\"font-size:16px\"><strong>\u26a0 Note on the Super Multi Box<\/strong><br>For DC combiners in the MW range with an extended protection and monitoring concept (Super Multi Box), a separate inquiry form is available. Please use the specifically designated form for this purpose. <\/p>\n\n\n\n<div class=\"wp-block-buttons alignwide is-content-justification-center is-layout-flex wp-container-core-buttons-is-layout-fb00162f wp-block-buttons-is-layout-flex\" style=\"padding-top:var(--wp--preset--spacing--50);padding-right:var(--wp--preset--spacing--80);padding-bottom:var(--wp--preset--spacing--50);padding-left:var(--wp--preset--spacing--80)\">\n<div class=\"wp-block-button has-custom-width wp-block-button__width-50 is-style-secondary dc-card\"><a class=\"wp-block-button__link has-neve-text-color-color has-text-color has-link-color has-border-color has-neve-text-color-border-color has-medium-font-size has-custom-font-size wp-element-button\" style=\"border-width:1px;border-top-left-radius:8px;border-top-right-radius:8px;border-bottom-left-radius:8px;border-bottom-right-radius:8px\">To the Super Multi Box inquiry \u2192<\/a><\/div>\n<\/div>\n<\/div>\n<\/div>\n\n\n\n<div class=\"wp-block-group alignfull has-nv-c-2-background-color has-background\" id=\"produkte\" style=\"border-top-left-radius:8px;border-top-right-radius:8px;border-bottom-left-radius:8px;border-bottom-right-radius:8px;padding-right:var(--wp--preset--spacing--50);padding-left:var(--wp--preset--spacing--50)\"><div class=\"wp-block-group__inner-container is-layout-constrained wp-container-core-group-is-layout-e59bffbc wp-block-group-is-layout-constrained\">\n<div class=\"wp-block-columns alignfull is-layout-flex wp-container-core-columns-is-layout-5b0bc1de wp-block-columns-is-layout-flex\" style=\"border-top-left-radius:8px;border-top-right-radius:8px;border-bottom-left-radius:8px;border-bottom-right-radius:8px;padding-top:var(--wp--preset--spacing--50);padding-right:var(--wp--preset--spacing--50);padding-bottom:var(--wp--preset--spacing--50);padding-left:var(--wp--preset--spacing--50)\">\n<div class=\"wp-block-column is-vertically-aligned-top animated fadeIn q3-product-card has-large-font-size is-layout-flow wp-block-column-is-layout-flow\" style=\"padding-top:var(--wp--preset--spacing--20);padding-right:var(--wp--preset--spacing--20);padding-bottom:var(--wp--preset--spacing--20);padding-left:var(--wp--preset--spacing--20)\">\n<div class=\"wp-block-cover aligncenter has-custom-content-position is-position-bottom-center\" style=\"border-top-left-radius:8px;border-top-right-radius:8px;border-bottom-left-radius:8px;border-bottom-right-radius:8px;padding-top:0;padding-right:var(--wp--preset--spacing--50);padding-bottom:0;padding-left:var(--wp--preset--spacing--50)\"><img loading=\"lazy\" decoding=\"async\" width=\"400\" height=\"400\" class=\"wp-block-cover__image-background wp-image-1733 size-full\" alt=\"Anfrage\" src=\"https:\/\/q3-energie.de\/wp-content\/uploads\/2026\/02\/Anfrage.webp\" data-object-fit=\"cover\" title=\"\" srcset=\"https:\/\/q3-energie.de\/wp-content\/uploads\/2026\/02\/Anfrage.webp 400w, https:\/\/q3-energie.de\/wp-content\/uploads\/2026\/02\/Anfrage-300x300.webp 300w, https:\/\/q3-energie.de\/wp-content\/uploads\/2026\/02\/Anfrage-150x150.webp 150w\" sizes=\"auto, (max-width: 400px) 100vw, 400px\" \/><span aria-hidden=\"true\" class=\"wp-block-cover__background has-neve-link-color-background-color has-background-dim-80 has-background-dim\"><\/span><div class=\"wp-block-cover__inner-container is-layout-constrained wp-container-core-cover-is-layout-0255ba1e wp-block-cover-is-layout-constrained\">\n<div style=\"height:10px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<h2 class=\"wp-block-heading has-text-align-center has-nv-text-dark-bg-color has-text-color has-link-color wp-elements-3a2e7059b5b7d7172d163d6ed0834015\" style=\"font-size:20px\">Project Inquiry PV String Combiner<\/h2>\n\n\n<div class=\"wp-block-image wp-duotone-unset-1\">\n<figure class=\"aligncenter size-thumbnail has-custom-border\"><img loading=\"lazy\" decoding=\"async\" width=\"150\" height=\"150\" src=\"https:\/\/q3-energie.de\/wp-content\/uploads\/2026\/02\/Anfrage-150x150.webp\" alt=\"Submit project inquiry\" class=\"wp-image-1733\" style=\"border-style:none;border-width:0px\" title=\"\" srcset=\"https:\/\/q3-energie.de\/wp-content\/uploads\/2026\/02\/Anfrage-150x150.webp 150w, https:\/\/q3-energie.de\/wp-content\/uploads\/2026\/02\/Anfrage-300x300.webp 300w, https:\/\/q3-energie.de\/wp-content\/uploads\/2026\/02\/Anfrage.webp 400w\" sizes=\"auto, (max-width: 150px) 100vw, 150px\" \/><\/figure>\n<\/div>\n\n\n<p class=\"has-nv-text-dark-bg-color has-text-color has-link-color wp-elements-672ed8e72fe222ca3c558b77bd319fd1 wp-block-paragraph\" style=\"font-size:16px\">Project-related design of PV string combiner boxes (SCB), string boxes, and DC protection concepts for PV systems up to 1,500 V DC.<\/p>\n\n\n\n<div class=\"wp-block-buttons is-layout-flex wp-container-core-buttons-is-layout-00436373 wp-block-buttons-is-layout-flex\">\n<div class=\"wp-block-button has-custom-width wp-block-button__width-100 is-style-primary q3-card-link\"><a class=\"wp-block-button__link has-medium-font-size has-custom-font-size wp-element-button\" href=\"https:\/\/neu.q3-energie.de\/produkte\/projektanfrage\/generatoranschlusskasten-gak\/\">Start DC connection box project inquiry \u2192<\/a><\/div>\n<\/div>\n<\/div><\/div>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-vertically-aligned-top animated fadeIn q3-product-card has-large-font-size is-layout-flow wp-block-column-is-layout-flow\" style=\"padding-top:var(--wp--preset--spacing--20);padding-right:var(--wp--preset--spacing--20);padding-bottom:var(--wp--preset--spacing--20);padding-left:var(--wp--preset--spacing--20)\">\n<div class=\"wp-block-cover aligncenter has-custom-content-position is-position-bottom-center\" style=\"border-top-left-radius:8px;border-top-right-radius:8px;border-bottom-left-radius:8px;border-bottom-right-radius:8px;padding-top:0;padding-right:var(--wp--preset--spacing--50);padding-bottom:0;padding-left:var(--wp--preset--spacing--50)\"><img loading=\"lazy\" decoding=\"async\" width=\"400\" height=\"400\" class=\"wp-block-cover__image-background wp-image-1732 size-full\" alt=\"PDF\" src=\"https:\/\/q3-energie.de\/wp-content\/uploads\/2026\/02\/PDF.webp\" data-object-fit=\"cover\" title=\"\" srcset=\"https:\/\/q3-energie.de\/wp-content\/uploads\/2026\/02\/PDF.webp 400w, https:\/\/q3-energie.de\/wp-content\/uploads\/2026\/02\/PDF-300x300.webp 300w, https:\/\/q3-energie.de\/wp-content\/uploads\/2026\/02\/PDF-150x150.webp 150w\" sizes=\"auto, (max-width: 400px) 100vw, 400px\" \/><span aria-hidden=\"true\" class=\"wp-block-cover__background has-neve-link-color-background-color has-background-dim-80 has-background-dim\"><\/span><div class=\"wp-block-cover__inner-container is-layout-constrained wp-container-core-cover-is-layout-0255ba1e wp-block-cover-is-layout-constrained\">\n<div style=\"height:10px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<h2 class=\"wp-block-heading has-text-align-center has-nv-text-dark-bg-color has-text-color has-link-color wp-elements-e9851e78ca0c0acfc64341b1671886fe\" style=\"font-size:20px\">DC Connection Technology Download Area<\/h2>\n\n\n<div class=\"wp-block-image wp-duotone-unset-2\">\n<figure class=\"aligncenter size-thumbnail has-custom-border\"><img loading=\"lazy\" decoding=\"async\" width=\"150\" height=\"150\" src=\"https:\/\/q3-energie.de\/wp-content\/uploads\/2026\/02\/PDF-150x150.webp\" alt=\"Visit our download area!\" class=\"wp-image-1732\" style=\"border-style:none;border-width:0px\" title=\"\" srcset=\"https:\/\/q3-energie.de\/wp-content\/uploads\/2026\/02\/PDF-150x150.webp 150w, https:\/\/q3-energie.de\/wp-content\/uploads\/2026\/02\/PDF-300x300.webp 300w, https:\/\/q3-energie.de\/wp-content\/uploads\/2026\/02\/PDF.webp 400w\" sizes=\"auto, (max-width: 150px) 100vw, 150px\" \/><\/figure>\n<\/div>\n\n\n<p class=\"has-nv-text-dark-bg-color has-text-color has-link-color wp-elements-703f000fbb1da4c7e11c956762ef9770 wp-block-paragraph\" style=\"font-size:16px\">Data sheets, circuit diagrams, certificates, and technical documentation for Q3 PV string combiner boxes (SCB) and DC combiners.<\/p>\n\n\n\n<div class=\"wp-block-buttons is-layout-flex wp-container-core-buttons-is-layout-00436373 wp-block-buttons-is-layout-flex\">\n<div class=\"wp-block-button has-custom-width wp-block-button__width-100 is-style-primary q3-card-link\"><a class=\"wp-block-button__link has-medium-font-size has-custom-font-size wp-element-button\" href=\"https:\/\/neu.q3-energie.de\/technische-downloads\/ac-anschlusstechnik\/\">Technical downloads DC box \u2192<\/a><\/div>\n<\/div>\n<\/div><\/div>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-vertically-aligned-top animated fadeIn q3-product-card has-large-font-size is-layout-flow wp-block-column-is-layout-flow\" style=\"padding-top:var(--wp--preset--spacing--20);padding-right:var(--wp--preset--spacing--20);padding-bottom:var(--wp--preset--spacing--20);padding-left:var(--wp--preset--spacing--20)\">\n<div class=\"wp-block-cover aligncenter has-custom-content-position is-position-bottom-center\" style=\"border-top-left-radius:8px;border-top-right-radius:8px;border-bottom-left-radius:8px;border-bottom-right-radius:8px;padding-top:0;padding-right:var(--wp--preset--spacing--50);padding-bottom:0;padding-left:var(--wp--preset--spacing--50)\"><img loading=\"lazy\" decoding=\"async\" width=\"400\" height=\"400\" class=\"wp-block-cover__image-background wp-image-2591 size-full\" alt=\"\" src=\"https:\/\/q3-energie.de\/wp-content\/uploads\/2026\/02\/Super_Multi_Box-DC-Combiner.webp\" data-object-fit=\"cover\" title=\"\" srcset=\"https:\/\/q3-energie.de\/wp-content\/uploads\/2026\/02\/Super_Multi_Box-DC-Combiner.webp 400w, https:\/\/q3-energie.de\/wp-content\/uploads\/2026\/02\/Super_Multi_Box-DC-Combiner-300x300.webp 300w, https:\/\/q3-energie.de\/wp-content\/uploads\/2026\/02\/Super_Multi_Box-DC-Combiner-150x150.webp 150w\" sizes=\"auto, (max-width: 400px) 100vw, 400px\" \/><span aria-hidden=\"true\" class=\"wp-block-cover__background has-neve-link-color-background-color has-background-dim-80 has-background-dim\"><\/span><div class=\"wp-block-cover__inner-container is-layout-constrained wp-container-core-cover-is-layout-0255ba1e wp-block-cover-is-layout-constrained\">\n<div style=\"height:10px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<h2 class=\"wp-block-heading has-text-align-center has-nv-text-dark-bg-color has-text-color has-link-color wp-elements-bc5a921ba37c5926f1ccb0c43d6c1ef0\" style=\"font-size:20px\">DC Combiner Super Multi Box<\/h2>\n\n\n<div class=\"wp-block-image wp-duotone-unset-3\">\n<figure class=\"aligncenter size-thumbnail has-custom-border\"><img loading=\"lazy\" decoding=\"async\" width=\"150\" height=\"150\" src=\"https:\/\/q3-energie.de\/wp-content\/uploads\/2026\/02\/Super_Multi_Box-DC-Combiner-150x150.webp\" alt=\"Super Multi Box DC Combiner\" class=\"wp-image-2591\" style=\"border-style:none;border-width:0px\" title=\"\" srcset=\"https:\/\/q3-energie.de\/wp-content\/uploads\/2026\/02\/Super_Multi_Box-DC-Combiner-150x150.webp 150w, https:\/\/q3-energie.de\/wp-content\/uploads\/2026\/02\/Super_Multi_Box-DC-Combiner-300x300.webp 300w, https:\/\/q3-energie.de\/wp-content\/uploads\/2026\/02\/Super_Multi_Box-DC-Combiner.webp 400w\" sizes=\"auto, (max-width: 150px) 100vw, 150px\" \/><\/figure>\n<\/div>\n\n\n<p class=\"has-nv-text-dark-bg-color has-text-color has-link-color wp-elements-db67c56733f66460f060dcd9b1218761 wp-block-paragraph\" style=\"font-size:16px\">DC combiner for solar parks and Agri-PV with an extended protection and monitoring concept and patented fault discrimination.<\/p>\n\n\n\n<div class=\"wp-block-buttons is-layout-flex wp-container-core-buttons-is-layout-00436373 wp-block-buttons-is-layout-flex\">\n<div class=\"wp-block-button has-custom-width wp-block-button__width-100 is-style-primary q3-card-link\"><a class=\"wp-block-button__link has-medium-font-size has-custom-font-size wp-element-button\" href=\"https:\/\/neu.q3-energie.de\/produkte\/dc-combiner-super-multi-box\/\">Discover Super Multi Box \u2192<\/a><\/div>\n<\/div>\n<\/div><\/div>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-vertically-aligned-top animated fadeIn q3-product-card has-large-font-size is-layout-flow wp-block-column-is-layout-flow\" style=\"padding-top:var(--wp--preset--spacing--20);padding-right:var(--wp--preset--spacing--20);padding-bottom:var(--wp--preset--spacing--20);padding-left:var(--wp--preset--spacing--20)\">\n<div class=\"wp-block-cover aligncenter has-custom-content-position is-position-bottom-center\" style=\"border-top-left-radius:8px;border-top-right-radius:8px;border-bottom-left-radius:8px;border-bottom-right-radius:8px;padding-top:0;padding-right:var(--wp--preset--spacing--50);padding-bottom:0;padding-left:var(--wp--preset--spacing--50)\"><img loading=\"lazy\" decoding=\"async\" width=\"751\" height=\"501\" class=\"wp-block-cover__image-background wp-image-2140 size-full\" alt=\"DC Anschlusstechnik\" src=\"https:\/\/neu.q3-energie.de\/wp-content\/uploads\/2026\/02\/DC-Anschlusstechnik.webp\" style=\"object-position:51% 58%\" data-object-fit=\"cover\" data-object-position=\"51% 58%\" title=\"\" srcset=\"https:\/\/q3-energie.de\/wp-content\/uploads\/2026\/02\/DC-Anschlusstechnik.webp 751w, https:\/\/q3-energie.de\/wp-content\/uploads\/2026\/02\/DC-Anschlusstechnik-300x200.webp 300w\" sizes=\"auto, (max-width: 751px) 100vw, 751px\" \/><span aria-hidden=\"true\" class=\"wp-block-cover__background has-neve-link-color-background-color has-background-dim-80 has-background-dim\"><\/span><div class=\"wp-block-cover__inner-container is-layout-constrained wp-container-core-cover-is-layout-0255ba1e wp-block-cover-is-layout-constrained\">\n<div style=\"height:10px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<h2 class=\"wp-block-heading has-text-align-center has-nv-text-dark-bg-color has-text-color has-link-color wp-elements-f6f0e408252faa65c103763eb4748407\" style=\"font-size:20px\">Customized DC solutions<\/h2>\n\n\n<div class=\"wp-block-image wp-duotone-unset-4\">\n<figure class=\"aligncenter size-thumbnail has-custom-border\"><img loading=\"lazy\" decoding=\"async\" width=\"150\" height=\"150\" src=\"https:\/\/neu.q3-energie.de\/wp-content\/uploads\/2026\/02\/DC-Anschlusstechnik-150x150.webp\" alt=\"DC Connection Technology\" class=\"wp-image-2140\" style=\"border-style:none;border-width:0px\" title=\"\"><\/figure>\n<\/div>\n\n\n<p class=\"has-nv-text-dark-bg-color has-text-color has-link-color wp-elements-71cf8bed95caa4e856422d714912ff82 wp-block-paragraph\" style=\"font-size:16px\">Project-specific string combiner boxes and string boxes for special requirements: special enclosures &amp; protection ratings<\/p>\n\n\n\n<div class=\"wp-block-buttons is-layout-flex wp-container-core-buttons-is-layout-00436373 wp-block-buttons-is-layout-flex\">\n<div class=\"wp-block-button has-custom-width wp-block-button__width-100 is-style-primary q3-card-link\"><a class=\"wp-block-button__link has-medium-font-size has-custom-font-size wp-element-button\" href=\"https:\/\/neu.q3-energie.de\/produkte\/dc-boxen\/\">Discover Q3 DC connection technology \u2192<\/a><\/div>\n<\/div>\n<\/div><\/div>\n<\/div>\n<\/div>\n<\/div><\/div>\n","protected":false},"excerpt":{"rendered":"<p>Typical planning errors in PV string combiners When designing string combiner boxes and DC combiner systems, detailed planning determines operational safety, ease of service, and yield. In practice, similar error patterns occur repeatedly \u2013 these can be reliably avoided through early coordination and dimensioning in accordance with standards. Parallel connection without a clean reverse current&hellip;&nbsp;<\/p>\n","protected":false},"author":1,"featured_media":7488,"parent":7465,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"neve_meta_sidebar":"","neve_meta_container":"","neve_meta_enable_content_width":"","neve_meta_content_width":0,"neve_meta_title_alignment":"","neve_meta_author_avatar":"","neve_post_elements_order":"","neve_meta_disable_header":"","neve_meta_disable_footer":"","neve_meta_disable_title":"","neve_meta_reading_time":"","_themeisle_gutenberg_block_has_review":false,"footnotes":""},"class_list":["post-7483","page","type-page","status-publish","has-post-thumbnail","hentry"],"jetpack_sharing_enabled":true,"_links":{"self":[{"href":"https:\/\/q3-energie.de\/en\/wp-json\/wp\/v2\/pages\/7483","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/q3-energie.de\/en\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/q3-energie.de\/en\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/q3-energie.de\/en\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/q3-energie.de\/en\/wp-json\/wp\/v2\/comments?post=7483"}],"version-history":[{"count":0,"href":"https:\/\/q3-energie.de\/en\/wp-json\/wp\/v2\/pages\/7483\/revisions"}],"up":[{"embeddable":true,"href":"https:\/\/q3-energie.de\/en\/wp-json\/wp\/v2\/pages\/7465"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/q3-energie.de\/en\/wp-json\/wp\/v2\/media\/7488"}],"wp:attachment":[{"href":"https:\/\/q3-energie.de\/en\/wp-json\/wp\/v2\/media?parent=7483"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}